Dell OptiPlex 5055 Ryzen CPU Tower OptiPlex 5055 Tower Owners Manual - Page 78
Storage Subsystem, Troubleshooting
View all Dell OptiPlex 5055 Ryzen CPU Tower manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
State S7 S8 S9 State Name USB MEM MBF Blinking Amber Pattern 3 blinks > short pause > 4 blinks > long pause > repeats 3 blinks > short pause > 5 blinks > long pause > repeats 3 blinks > short pause > 6 blinks > long pause > repeats Problem Description Suggested Resolution Storage Subsystem failure Possible storage device configuration in progress or storage subsystem failure. If customer can assist to troubleshoot, narrow down the issue by removing one by one storages on motherboard to determine which one failed. If identified the storage failed, replace the storage. If identified the storage failed, replace the storage. Memory configuration or incompatible error Memory subsystem configuration activity is in progress. No memory modules were detected. If customer can assist to troubleshoot, narrow down the issue by removing one by one the memory on motherboard to determine which one failed. Also, combining the configuration to validate appropriate combination. If identified the component failed, replace the component. If none of the component failed, replace the motherboard. System board failure Fatal system board failure detected. If customer can assist to troubleshoot, narrow down the issue by removing one by one the component on motherboard to determine which one failed. If identified any of the component failed, replace the component. If none of the component failed, replace the motherboard. 78 Troubleshooting