Width Error: Slot - bios
View all Dell PowerEdge 1950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Table 1-1. System Messages (continued) Message Causes Corrective Actions PCI BIOS failed to install PCIe device BIOS (Option Reseat the expansion ROM) checksum failure card(s). Ensure that all detected during shadowing. appropriate cables are Cables to expansion card(s) securely connected to the loose; faulty or improperly expansion card(s). If the installed expansion card(s). problem persists, see "Troubleshooting System Expansion Cards" in the Hardware Owner's Manual. PCIe Degraded Link Faulty system board or riser See "Getting Help" in the Width Error: board. Hardware Owner's Manual. Embedded device Expected Link Width is n Actual Link Width is n PCIe Degraded Link Width Error: Integrated device Expected Link Width is n Actual Link Width is n The specified PCIe device is faulty or improperly installed. For a SAS controller daughter card, reseat the card in the dedicated PCIe connector. See "Installing a SAS Controller Daughter Card" in the Hardware Owner's Manual. If the problem persists, see "Getting Help" in the Hardware Owner's Manual. PCIe Degraded Link Faulty or improperly Width Error: Slot n installed PCIe card in Expected Link Width the specified slot. is n Actual Link Width is n Reseat the PCIe card in the specified slot number. See "Expansion Cards" in the Hardware Owner's Manual. If the problem persists, see "Getting Help" in the Hardware Owner's Manual. PCIe Training Error: Embedded device Faulty system board or riser board. See "Getting Help" in the Hardware Owner's Manual. 12 Information Update