Dell PowerEdge 1950 Information Update - Page 16

Table 1-2., LCD Status Messages, Causes, Corrective Actions - raid setup

Page 16 highlights

Table 1-2. LCD Status Messages Code N/A E1000 E1118 E1211 Text Causes Corrective Actions SYSTEM NAME A 62-character This message is for string that can be information only. defined by the user You can change the in the System Setup system ID and program. name in the System The SYSTEM NAME Setup program. See is displayed under "Using the System the following Setup Program" in conditions: the Hardware • The system is Owner's Manual. powered on. • The power is off and active errors are displayed. FAILSAFE, Call Check the system See "Getting Help" Support event log for critical in the Hardware failure events. Owner's Manual. CPU Temp Interface The BMC is unable Turn off power to to determine the system and the CPU(s) restart the system. temperature status. If the problem Consequently, the persists, see BMC increases "Getting Help" the CPU fan speed in the Hardware to maximum Owner's Manual. as a precautionary measure. ROMB Batt RAID battery is Reseat the RAID either missing, bad, battery connector. or unable to See the "RAID recharge due to Battery" and see thermal issues. "Troubleshooting System Cooling Problems" in the Hardware Owner's Manual. 16 Information Update

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194

16
Information Update
Table 1-2.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character
string that can be
defined by the user
in the System Setup
program.
The
SYSTEM NAME
is displayed under
the following
conditions:
The system is
powered on.
The power is off
and active errors
are displayed.
This message is for
information only.
You can change the
system ID and
name in the System
Setup program. See
"Using the System
Setup Program" in
the
Hardware
Owner’s Manual
.
E1000
FAILSAFE, Call
Support
Check the system
event log for critical
failure events.
See "Getting Help"
in the
Hardware
Owner’s Manual
.
E1118
CPU Temp
Interface
The BMC is unable
to determine
the CPU(s)
temperature status.
Consequently, the
BMC increases
the CPU fan speed
to maximum
as a precautionary
measure.
Turn off power to
the system and
restart the system.
If the problem
persists, see
"Getting Help"
in the
Hardware
Owner’s Manual
.
E1211
ROMB Batt
RAID battery is
either missing, bad,
or unable to
recharge due to
thermal issues.
Reseat the RAID
battery connector.
See the "RAID
Battery" and see
"Troubleshooting
System Cooling
Problems" in the
Hardware Owner’s
Manual
.