Dell PowerEdge M1000e Technical Guide - Page 63

Many update of drivers & Firmware via Remote File Share w/ Repository Manager - cmc reset

Page 63 highlights

Dell o Monitoring and alerting for chassis environmental conditions or component health thresholds. This includes but is not limited to the following:  Real time power consumption  Power supplies  Fans  Power allocation  Temperature  CMC redundancy o I/O fabric consistency o Consolidated Status Reporting & Event Logs  Email & SNMP alerting  Support for Remote Syslog  Blade Events displayed in CMC o Consolidated Chassis/Blade/IO Inventory o ―Virtual Server Reseat‖ simulates blade removal/insertion o Remotely blink LEDs to Identify Components Updating o Reporting of Firmware versions o 1:Many iDRAC Firmware update o Consolidated CMC and iKVM F/W update o 1:Many update of drivers & Firmware via Remote File Share (w/ Repository Manager) o 2 x 10/100/1000Mb Ethernet ports + 1 serial port Real Time Power/Thermal Monitoring and Management o Consolidated Chassis/Blade Power Reporting o Power budget management and allocation o Real Time System AC Power Consumption with reset-able peak and minimum values o System level power limiting and slot based power prioritization o Manages Dynamic Power Engagement functionality o Manages fan speed control o Power sequencing of modules in conjunction with the defined chassis power states Separate management network o Configuration of the embedded management switch, which facilitates external access to manageable modules o Provides connection from management network to iDRAC on each of the blades and the management interfaces on the integrated I/O Modules o 2nd Ethernet port supports daisy chaining of CMCs for improved cable management Security o Local Authentication &/or AD Integration  OpenLDAP coming in CMC 3.0 o Supports multiple levels of user roles and permissions for control of chassis, IO, &/or server blades, including Microsoft Active Directory o IPv6 Support o VLAN tagging for iDRAC, CMC, and IOMs o Two Factor Authentication w/ SmartCard o Single Sign On using OS credentials (with AD) o Private Key Authentication (PK Auth) o Secure Web (SSL) and CLI (Telnet/SSH) interfaces Support for Industry-Standard Interfaces o SMASH CLP o WSMAN o CIM XML PowerEdge M1000e Technical Guide 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

Dell
PowerEdge M1000e Technical Guide
62
o
Monitoring and alerting for chassis environmental conditions or component health
thresholds. This includes but is not limited to the following:
Real time power consumption
Power supplies
Fans
Power allocation
Temperature
CMC redundancy
o
I/O fabric consistency
o
Consolidated Status Reporting & Event Logs
Email & SNMP alerting
Support for Remote Syslog
Blade Events displayed in CMC
o
Consolidated Chassis/Blade/IO Inventory
o
―Virtual Server Reseat‖ simulates blade removal/insertion
o
Remotely blink LEDs to Identify Components
Updating
o
Reporting of Firmware versions
o
1:Many iDRAC Firmware update
o
Consolidated CMC and iKVM F/W update
o
1:Many update of drivers & Firmware via Remote File Share (w/ Repository Manager)
o
2 x 10/100/1000Mb Ethernet ports + 1 serial port
Real Time Power/Thermal Monitoring and Management
o
Consolidated Chassis/Blade Power Reporting
o
Power budget management and allocation
o
Real Time System AC Power Consumption with reset-able peak and minimum values
o
System level power limiting and slot based power prioritization
o
Manages Dynamic Power Engagement functionality
o
Manages fan speed control
o
Power sequencing of modules in conjunction with the defined chassis power states
Separate management network
o
Configuration of the embedded management switch, which facilitates external access
to manageable modules
o
Provides connection from management network to iDRAC on each of the blades and
the management interfaces on the integrated I/O Modules
o
2nd Ethernet port supports daisy chaining of CMCs for improved cable management
Security
o
Local Authentication &/or AD Integration
OpenLDAP coming in CMC 3.0
o
Supports multiple levels of user roles and permissions for control of chassis, IO, &/or
server blades, including Microsoft Active Directory
o
IPv6 Support
o
VLAN tagging for iDRAC, CMC, and IOMs
o
Two Factor Authentication w/ SmartCard
o
Single Sign On using OS credentials (with AD)
o
Private Key Authentication (PK Auth)
o
Secure Web (SSL) and CLI (Telnet/SSH) interfaces
Support for Industry-Standard Interfaces
o
SMASH CLP
o
WSMAN
o
CIM XML