Dell PowerEdge R300 Hardware Owner's Manual (PDF) - Page 28
PCI SERR Slot, E1714 Unknown Err, E171F PCIE Fatal, PCIE Fatal, Err Slot - fatal error e171f
View all Dell PowerEdge R300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-6. LCD Status Messages (continued) Code Text Causes Corrective Actions E1712 PCI SERR B## D## F## The system BIOS has Remove and reseat the reported a PCI system error PCIe expansion cards. If on a component that resides the problem persists, see in PCI configuration space "Troubleshooting at bus ##, device ##, Expansion Cards" on function ##. page 147. PCI SERR Slot # The system BIOS has Remove and reseat the reported a PCI system error PCIe expansion cards. If on a component that resides the problem persists, see in the specified slot. "Troubleshooting Expansion Cards" on page 147. E1714 Unknown Err The system BIOS has See "Getting Help" on determined that there has page 165. been an error in the system, but is unable to determine its origin. E171F PCIE Fatal Err B## D## F## The system BIOS has Remove and reseat the reported a PCIe fatal error PCIe expansion cards. If on a component that resides the problem persists, see in PCIe configuration space "Troubleshooting at bus ##, device ##, Expansion Cards" on function ##. page 147. PCIE Fatal Err Slot # The system BIOS has Remove and reseat the reported a PCIe fatal error PCIe expansion cards. If on a component that resides the problem persists, see in the specified slot. "Troubleshooting Expansion Cards" on page 147. E1810 HDD ## Fault The SAS subsystem has See "Troubleshooting a determined that hard drive Hard Drive" on page 142. ## has experienced a fault. 28 About Your System