Table 1-6. LCD Status Messages (continued) Code Text E1811 HDD ## Rbld Abrt E1812 HDD ## Removed E1913 CPU & Firmware Mismatch E1A12 PCI Rsr Config E1A12 PCI Rsr Missing E1A14 SAS Cable A E1A15 SAS Cable B Causes Corrective Actions The specified hard drive has See "Troubleshooting a experienced a rebuild abort. Hard Drive" on page 142. If the problem persists, see your RAID documentation. The specified hard drive has Information only. been removed from the system. The BMC firmware does not Update to the latest BMC support the CPU. firmware. See the BMC User's Guide for more information on setup and use of BMC. One or all of the PCIe risers Reinstall the missing riser is configured incorrectly, card(s). preventing the system from powering on. One or all of the PCIe risers Check that all is missing, preventing the connections are secure system from powering on. and correctly positioned. SAS cable A is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 165. SAS cable B is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 165. About Your System 29