Dell PowerEdge R300 Hardware Owner's Manual (PDF) - Page 42
Warning: A fatal, Warning! No micro - bios update
View all Dell PowerEdge R300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
Table 1-7. System Messages (continued) Message Causes Corrective Actions Unsupported RAID key detected. The RAID key installed in Information only. the system is not supported on this system. Utility partition not available The key was Create a utility partition on pressed during POST, but the boot hard drive. See the no utility partition exists CDs that came with your on the boot hard drive. system. Warning: A fatal error has caused system reset! Please check the system event log! A fatal system error occurred and caused the system to reboot. Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 123 for any faulty components specified in the SEL. Warning! No micro Microcode update failed. Update the BIOS firmware. code update loaded See "Getting Help" on for processor n page 165. Warning! Detected missing RAID hardware for the embedded RAID subsystem. RAID key or RAID DIMM Information only. missing when system is in RAID mode. Warning! Detected mode change from SCSI to RAID on channel x of the embedded RAID subsystem. Embedded RAID subsystem configuration has changed in System Setup. See "Using the System Setup Program" on page 46. Warning! Detected mode change from RAID to SCSI on channel x of the embedded RAID subsystem. Embedded RAID subsystem configuration has changed in System Setup. See "Using the System Setup Program" on page 46. 42 About Your System