Dell PowerEdge R6525 iDRAC9 with Lifecycle Controller Version 3.42.42.42 Relea - Page 12

Virtual Console with Java plug-in

Page 12 highlights

6 Known issues - To be fixed in future releases Storage devices not found in iDRAC Description Workaround Systems affected Tracking number If you disable the external slot that is connected to PERC, iDRAC will not detect the PERC card or storage devices present in the server. Remove the PERC card from the external slot that needs to be disabled and powercycle the system. All system supported by this release. 113901 Hot-plugged PCIe SSDs not detected Description Workaround Systems affected Tracking number Removing all PCIe SSDs connected behind a particular PCIe Extender and performing a warm reboot may cause iDRAC to not detect subsequent hot-plugs on that extender. With the hot-plugged drive(s) still in the system, perform a cold reboot of the host. All system supported by this release. 116735 NIC or FC device slot listed in hardware inventory even when disabled in BIOS Description Workaround Systems affected Tracking number For some NIC or FC cards, even when the device slot is disabled in BIOS, the slot may still get listed in the hardware inventory. N/A All system supported by this release. 104535 button in Virtual Console with Java plug-in Description Workaround Systems affected Tracking number Button does not display the localized name, you may see the button's English variable name with no online help support. The intent of this button is to reset keyboard mouse functionality without having user to restart the Virtual Console Keyboard and Mouse reset functionality works. Does not disrupt the end user experience, only impairs the aesthetic. All systems supported by this release. 119759 12 Known issues - To be fixed in future releases

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

Known issues — To be fixed in future releases
Storage devices not found in iDRAC
Description
If you disable the external slot that is connected to PERC, iDRAC will not detect the PERC card or storage
devices present in the server.
Workaround
Remove the PERC card from the external slot that needs to be disabled and powercycle the system.
Systems affected
All system supported by this release.
Tracking number
113901
Hot-plugged PCIe SSDs not detected
Description
Removing all PCIe SSDs connected behind a particular PCIe Extender and performing a warm reboot may cause
iDRAC to not detect subsequent hot-plugs on that extender.
Workaround
With the hot-plugged drive(s) still in the system, perform a cold reboot of the host.
Systems affected
All system supported by this release.
Tracking number
116735
NIC or FC device slot listed in hardware inventory
even when disabled in BIOS
Description
For some NIC or FC cards, even when the device slot is disabled in BIOS, the slot may still get listed in the
hardware inventory.
Workaround
N/A
Systems affected
All system supported by this release.
Tracking number
104535
<Keyboard_Mouse_USB_reset_warning> button in
Virtual Console with Java plug-in
Description
Button does not display the localized name, you may see the button's English variable name with no online help
support. The intent of this button is to reset keyboard mouse functionality without having user to restart the
Virtual Console
Workaround
Keyboard and Mouse reset functionality works. Does not disrupt the end user experience, only impairs the
aesthetic.
Systems affected
All systems supported by this release.
Tracking number
119759
6