Dell PowerEdge XE2420 EMC Technical Specifications - Page 29
EDSFF LED indicators
![]() |
View all Dell PowerEdge XE2420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 40. Drive indicator codes (continued) Drive status indicator code Off Condition Indicates that the drive is ready for removal. NOTE: The drive status indicator remains off until all drives are initialized after the system is powered on. Drives are not ready for removal during this time. Blinks green, amber, and then powers off Blinks amber four times per second Blinks green slowly Solid green Blinks green for three seconds, amber for three seconds, and then powers off after six seconds Indicates that there is an expected drive failure. Indicates that the drive has failed. Indicates that the drive is rebuilding. Indicates that the drive is online. Indicates that the rebuild has stopped. EDSFF LED indicators Figure 11. EDSFF LED indicators 1. Drive activity LED indicator 2. Drive status LED indicator Table 41. EDSFF LED indicators Green status indicator code OFF ON 4Hz flashing NA Amber status indicator code OFF OFF OFF 4Hz flashing ON Two fast blinks at 4Hz and pause for 0.5 seconds 1Hz flashing 1Hz flashing Drive condition Indicates that the drive is offline. Indicates that the drive is online. Indicates that there is activity on the drive. Indicates that the drive is being identified or preparing for removal. Indicates that the drive has failed. Indicates that there is an expected drive failure (SMART) . Indicates that the drives rebuilding is aborted. Indicates that the drive is rebuilding. System diagnostics and indicator codes 29
![](/manual_guide/products/dell-poweredge-xe2420-emc-technical-specifications-44aed08/29.png)