Dell PowerStore 3200T EMC PowerStore Installation and Service Guide for PowerS - Page 140

Installing the front bezel, Verify the operation of a replacement drive, Return a faulted part

Page 140 highlights

Installing the front bezel Steps 1. Align the bezel with the enclosure. 2. Gently push the bezel into place on the cabinet until it latches. 3. If the bezel has a key lock, lock the bezel with the provided key. CL5262 Figure 167. Installing the bezel Verify the operation of a replacement drive Steps 1. From PowerStore Manager, select Hardware. 2. Select the appliance where you replaced the drive. 3. On the Components card, under Drives, expand ExpansionEnclosure and select the drive. The status of the replacement drive should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore Manager. If the status does not change, ensure that the drive is correctly seated, or contact your service provider. 4. Click Stop Blink LED. Return a faulted part About this task For US customers, return defective material within five business days. For International customers, return defective material within 10 business days. The materials required to return your defective part are supplied with the good part shipment. Steps 1. Package the faulted part in the shipping box that contained the replacement part. 2. Ship the failed part to your service provider as described in the instructions that were included with the replacement part. 3. For more information about returning customer-replaceable parts: a. Open PowerStore Manager. b. Click Settings on the upper right of the screen. c. Click General Support. d. Under Drives, Power Supplies, and Other Parts, click Return Part. 140 NVMe expansion enclosure service procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

Installing the front bezel
Steps
1.
Align the bezel with the enclosure.
2.
Gently push the bezel into place on the cabinet until it latches.
3.
If the bezel has a key lock, lock the bezel with the provided key.
CL5262
Figure 167. Installing the bezel
Verify the operation of a replacement drive
Steps
1.
From PowerStore Manager, select
Hardware
.
2.
Select the appliance where you replaced the drive.
3.
On the
Components
card, under
Drives
, expand
ExpansionEnclosure
and select the drive.
The status of the replacement drive should read
Healthy
. If the status is still
Faulted
, wait a few minutes and refresh
PowerStore Manager. If the status does not change, ensure that the drive is correctly seated, or contact your service
provider.
4.
Click
Stop Blink LED
.
Return a faulted part
About this task
For US customers, return defective material within five business days. For International customers, return defective material
within 10 business days. The materials required to return your defective part are supplied with the good part shipment.
Steps
1.
Package the faulted part in the shipping box that contained the replacement part.
2.
Ship the failed part to your service provider as described in the instructions that were included with the replacement part.
3.
For more information about returning customer-replaceable parts:
a.
Open PowerStore Manager.
b.
Click
Settings
on the upper right of the screen.
c.
Click
General Support
.
d.
Under
Drives, Power Supplies, and Other Parts
, click
Return Part
.
140