Dell PowerStore 3200T EMC PowerStore Installation and Service Guide for PowerS - Page 77

Before you begin, Identify a faulted I/O module from PowerStore Manager

Page 77 highlights

Before you begin CAUTION: Before starting this procedure, use the PowerStore Manager Hardware view and Alerts view to verify that the appliance and peer node are healthy with no outstanding alerts. If multiple nodes need to be removed while performing this procedure, repeat this verification for each affected node before proceeding to remove the next node. If necessary, contact your service provider before starting the replacement procedure. Identify a faulted I/O module from PowerStore Manager Before you replace an I/O module, ensure that you have identified its location within the system. Using PowerStore Manager, you can identify and locate a faulted I/O module. Steps 1. From PowerStore Manager, select Hardware. 2. Select the appliance that includes the I/O module that you need to replace. 3. On the Components card, under Rear View, expand BaseEnclosure. 4. Expand the node that includes the I/O module, and then select the relevant IoModule. Faulted parts appear in red in the image of the system, and report a status of Faulted in the State field. Base enclosure I/O module LEDs Use the fault LEDs to identify the faulted part. NOTE: The ports look different depending on whether they are for copper or optical connections. The image below shows ports for copper cables. Figure 77. Base enclosure I/O module LEDs Table 6. Base enclosure I/O module LEDs LED Location Port link Power/Fault State Green or blue Off Green Amber Power down the node Power down the node as described in Power control procedures. Description Link up Link down Power on Fault Base enclosure service procedures 77

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

Before you begin
CAUTION:
Before starting this procedure, use the PowerStore Manager Hardware view and Alerts view to verify
that the appliance and peer node are healthy with no outstanding alerts. If multiple nodes need to be removed
while performing this procedure, repeat this verification for each affected node before proceeding to remove
the next node. If necessary, contact your service provider before starting the replacement procedure.
Identify a faulted I/O module from PowerStore Manager
Before you replace an I/O module, ensure that you have identified its location within the system. Using PowerStore Manager,
you can identify and locate a faulted I/O module.
Steps
1.
From PowerStore Manager, select
Hardware
.
2.
Select the appliance that includes the I/O module that you need to replace.
3.
On the
Components
card, under
Rear View
, expand
BaseEnclosure
.
4.
Expand the node that includes the I/O module, and then select the relevant
IoModule
.
Faulted parts appear in red in the image of the system, and report a status of
Faulted
in the
State
field.
Base enclosure I/O module LEDs
Use the fault LEDs to identify the faulted part.
NOTE:
The ports look different depending on whether they are for copper or optical connections. The image below shows
ports for copper cables.
Figure 77. Base enclosure I/O module LEDs
Table 6. Base enclosure I/O module LEDs
LED
Location
State
Description
Port link
Green or blue
Link up
Off
Link down
Power/Fault
Green
Power on
Amber
Fault
Power down the node
Power down the node as described in
Power control procedures
.
Base enclosure service procedures
77