Dell PowerVault NX3500 Hardware Owner's Manual - Page 30
SAS cable B, E2011 Memory
View all Dell PowerVault NX3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Table 1-3. LCD Status Messages (continued) Code E1A15 E1A1D E2010 E2011 E2012 E2013 E2014 Text Causes Corrective Actions SAS cable B SAS cable B is missing failure. Check or bad. connection. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 113. Control panel USB cable not detected. Check cable. USB cable to the control panel is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 113. Memory not detected. No memory was detected in the system. Inspect DIMMs. Install memory or reseat memory modules. See "Troubleshooting System Memory" on page 97. Memory configuration failure. Check DIMMs. Memory detected, but is not configurable. Error detected during memory configuration. See "Troubleshooting System Memory" on page 97. Memory Memory configured, but is See "Troubleshooting configured but unusable. System Memory" on unusable. page 97. Check DIMMs. BIOS unable to The system BIOS failed to See "Troubleshooting shadow memory. copy its flash image into System Memory" on Check DIMMs. memory. page 97. CMOS RAM CMOS failure. CMOS failure. Power RAM not functioning cycle AC. properly. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 113. 30 About Your Solution