Table 1-4., System Messages, Message, Causes, Corrective Actions, Alert! Power
View all Dell PowerVault NX3500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Table 1-4. System Messages Message Causes Corrective Actions Alert! iDRAC6 not The iDRAC6 is not Wait for the system to responding. responding to BIOS reboot. Rebooting. communication either because it is not functioning properly or has not completed initialization. The system will reboot. Alert! iDRAC6 not The iDRAC6 has hung. responding. Power required may exceed PSU wattage. Alert! Continuing system boot The iDRAC6 was remotely reset while system was booting. After AC recovery, the iDRAC6 takes longer than normal to boot. accepts the risk that system may power down without warning. Remove AC power to the system for 10 seconds and restart the system. Alert! Power required exceeds PSU wattage. Check PSU and system configuration. The system configuration of processor, memory modules, and expansion cards may not be supported by the power supplies. Alert! Continuing system boot accepts the risk that system may power down without warning. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with High Output power supplies to use the components. See "Power Supplies" on page 77. 36 About Your Solution