B B.1 Validated components The following tables include the hardware, software, and firmware used to configure and validate the examples in this guide. Dell EMC PowerSwitches Switches and OS versions Qty Item 2 Dell EMC PowerSwitch S5248F-ON leaf switch 4 Dell EMC PowerSwitch S4148U-ON leaf switch 2 Dell EMC PowerSwitch Z9264-ON spine switch 1 Dell EMC PowerSwitch S3048-ON management switch OS Version 10.4.3.1.154 10.4.3.1.154 10.4.3.1.154 10.4.3.1.154 B.2 B.3 Note: Leaf switches used for this deployment must support native VXLAN routing (RIOT). As of this writing, this includes Dell EMC S41xx-ON and S52xx-ON series, S4048T-ON and S6010-ON switches. PowerEdge R740xd Servers PowerEdge R740xd components Qty per server Item 2 Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz (16 cores) 4 16GB DDR4 DIMM (64GB total) 10 400GB SAS SSD 1 Dell HBA330 Storage Controller 1 QLogic FastLinQ QL41262HxCU-DE 2x25GbE SFP28 1 Intel X710 2x10GbE SFP+/i350 2x1GbE BASE-T rNDC - BIOS - iDRAC with Lifecycle Controller Firmware 16.17.00.03 14.07.50 18.8.9 1.6.12 3.21.26.22 VMware software VMware software versions Item Version VMware ESXi 6.7.0 Update 1 build 10764712 - Dell EMC customized image version A04 VMware vCenter Server Appliance 6.7 Update 1 - build 10244845 (Includes vSphere Web Client) 64 Dell EMC Networking Virtualization Overlay with BGP EVPN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

64
Dell EMC Networking Virtualization Overlay with BGP EVPN
B
Validated components
The following tables include the hardware, software, and firmware used to configure and validate the
examples in this guide.
B.1
Dell EMC PowerSwitches
Switches and OS versions
Qty
Item
OS Version
2
Dell EMC PowerSwitch S5248F-ON leaf switch
10.4.3.1.154
4
Dell EMC PowerSwitch S4148U-ON leaf switch
10.4.3.1.154
2
Dell EMC PowerSwitch Z9264-ON spine switch
10.4.3.1.154
1
Dell EMC PowerSwitch S3048-ON management switch
10.4.3.1.154
Note:
Leaf switches used for this deployment must support native VXLAN routing (RIOT). As of this writing,
this includes Dell EMC S41xx-ON and S52xx-ON series, S4048T-ON and S6010-ON switches.
B.2
PowerEdge R740xd Servers
PowerEdge R740xd components
Qty per
server
Item
Firmware
2
Intel(R) Xeon(R) Gold 6130 CPU @ 2.10GHz (16 cores)
-
4
16GB DDR4 DIMM (64GB total)
-
10
400GB SAS SSD
-
1
Dell HBA330 Storage Controller
16.17.00.03
1
QLogic FastLinQ QL41262HxCU-DE 2x25GbE SFP28
14.07.50
1
Intel X710 2x10GbE SFP+/i350 2x1GbE BASE-T rNDC
18.8.9
-
BIOS
1.6.12
-
iDRAC with Lifecycle Controller
3.21.26.22
B.3
VMware software
VMware software versions
Item
Version
VMware ESXi
6.7.0 Update 1 build 10764712 - Dell EMC customized image
version A04
VMware vCenter Server Appliance
6.7 Update 1
build 10244845 (Includes vSphere Web Client)