Dell S4048-ON EMC PowerSwitch Installation Guide March 2021 - Page 9

LED behavior, Table 1. S4048-ON LED behavior - stacking

Page 9 highlights

LED behavior The following S4048-ON switch LED behavior is seen during open networking installation environment (ONIE) operations: Figure 5. S4048-ON LEDs 1. Master LED 2. System LED 3. Power LED 4. Fan LED 5. Locator LED 6. SFP+ link/activity LEDs 7. Stack LED 8. USB port LED 9. QSFP+ link/activity LEDs Table 1. S4048-ON LED behavior LED System Status/Health LED Power LED MASTER LED FAN LED PSU LED Description ● Solid green-Normal operation ● Flashing green-Booting ● Solid amber-Critical system error ● Flashing amber-Non-critical system error, fan failure, or power supply failure ● Off-No power ● Solid Green-Normal ● Solid amber-POST is in process ● Flashing amber-Power supply failed ● Off-Switch is in Stacking Slave mode ● Solid green-System is in Stacking Master or Standalone mode ● Solid green-fan powered and running at the expected RPM ● Solid amber-fan failed including incompatible airflow direction when you insert the PSU or fan trays with differing airflows ● Solid green-Normal operation ● Solid amber-Power supply critical event causing a shutdown The S4048-ON switch 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

LED behavior
The following S4048–ON switch LED behavior is seen during open networking installation environment (ONIE) operations:
Figure 5. S4048–ON LEDs
1.
Master LED
2.
System LED
3.
Power LED
4.
Fan LED
5.
Locator LED
6.
SFP+ link/activity LEDs
7.
Stack LED
8.
USB port LED
9.
QSFP+ link/activity LEDs
Table 1. S4048–ON LED behavior
LED
Description
System Status/Health LED
Solid green—Normal operation
Flashing green—Booting
Solid amber—Critical system error
Flashing amber—Non-critical system error, fan failure, or
power supply failure
Power LED
Off—No power
Solid Green—Normal
Solid amber—POST is in process
Flashing amber—Power supply failed
MASTER LED
Off—Switch is in Stacking Slave mode
Solid green—System is in Stacking Master or Standalone
mode
FAN LED
Solid green—fan powered and running at the expected
RPM
Solid amber—fan failed including incompatible airflow
direction when you insert the PSU or fan trays with
differing airflows
PSU LED
Solid green—Normal operation
Solid amber—Power supply critical event causing a
shutdown
The S4048–ON switch
9