Dell S5248F-ON EMC Solutions for Microsoft Azure Stack HCI Networking Guide - Page 53
Get-NetAdapterQos -name Slot 2
![]() |
View all Dell S5248F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
10.11.2 Get-NetAdapterQos Use the Get-NetAdapterQos cmdlet to verify the NIC's DCB operational parameters. Verify the OperationalTrafficClasses bandwidth and priorities match those configured on the switch, shown in Table 11, and OperationalFlowControl is enabled for priority 3 and 5 traffic as configured on the switch, shown in Table 12. Note: The following output is from the Mellanox adapter. The output for the QLogic adapter is similar. Use the Get-NetAdapter cmdlet to retrieve the name for the associated adapter. PS> Get-NetAdapterQos -name "Slot 2*" Name Enabled Capabilities : SLOT 2 Port 2 : True : Hardware Current -------- ------- MacSecBypass : NotSupported NotSupported DcbxSupport : None None NumTCs(Max/ETS/PFC) : 8/8/8 8/8/8 OperationalTrafficClasses : TC TSA -- --0 ETS 1 ETS 2 ETS Bandwidth Priorities 49% 0-2,4,6-7 50% 3 1% 5 OperationalFlowControl : Priorities 3,5 Enabled OperationalClassifications : Protocol Port/Type Priority Default 0 NetDirect 445 3 Name Enabled Capabilities : SLOT 2 Port 1 : True : Hardware Current -------- ------- MacSecBypass : NotSupported NotSupported DcbxSupport : None None NumTCs(Max/ETS/PFC) : 8/8/8 8/8/8 OperationalTrafficClasses : TC TSA -- --0 ETS 1 ETS 2 ETS Bandwidth Priorities 49% 0-2,4,6-7 50% 3 1% 5 OperationalFlowControl : Priorities 3,5 Enabled OperationalClassifications : Protocol Port/Type Priority Default 0 NetDirect 445 3 53 Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide
![](/manual_guide/products/dell-powerswitch-s3048on-emc-solutions-microsoft-azure-stack-hci-networking-guide-ac27284/53.png)