Dewalt DW0330S Instruction Manual - Page 26

Specifications

Page 26 highlights

E Specifications DW0165 & DW0165S DW0330S Range 6in to 165ft (0.15m to 50m) 6in to 330ft (0.15m to 100m) Measuring Accuracy1 up to 10m: 1/16in (1.5mm) 10m-30m: 0.078in/5/64in) additional (+/- 0.15mm/m) >30m: +/- 0.002in/ft (+/- 0.2mm/m) Resolution2 1/16in (1mm) Laser Power Class 2 ≤ 1mW @ 620-690nm or Class 3R ≤ 5mW @ 620-690nm Laser Automatic Switch-off 30s Unit Automatic Switch-off By default, 90s. User can set to 30s, 60s, or 300s Continuous Measuring Yes Area Yes Volume Yes Pythagoras 2-Point Yes Endpiece to measure from Yes corners 3 Battery Life (3 x AAA) Up to 3000 Measurements (2500 with ; DW0165S & DW0330S) Dimension (H x D x W) 4.72 x 1.91 x 1.02in (120 x 48.5 x 26mm) Weight (with Batteries) 9.88oz (280g) Storage Temperature Range 14° F ~ 140° F (-10° C ~ +60 C) Operating Temperature Range 32° F ~ 104° F (0° C ~ +40° C) 1Measuring Accuracy depends on the current conditions: • Under favorable conditions (good target surface and room temperature), up to 33ft (10m). • Under unfavorable conditions (bright sunlight, a very weak reflecting target surface, or large temperature fluctuations), the error can increase by to ± 0.003 in/ft (± 0.25mm/m) for distances over 33ft (10m). 2Resolution is the finest measurement you can see, 1/16" (1mm). 3Flip open the endpiece at the bottom of the tool when you need to fit the tool into corners or grooves that are not at 180° angles. If a corner is at 90°, the endpiece can be used to hold the tool up against something. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

26
E
Specifications
DW0165 & DW0165S
DW0330S
Range
6in to 165ft
(0.15m to 50m)
6in to 330ft
(0.15m to 100m)
Measuring Accuracy
1
up to 10m:
1/16in (1.5mm)
10m-30m:
0.078in/5/64in) additional (+/- 0.15mm/m)
>30m:
+/- 0.002in/ft (+/- 0.2mm/m)
Resolution
2
1/16in (1mm)
Laser Power
Class 2
≤ 1mW @ 620-690nm or
Class 3R
≤ 5mW @ 620-690nm
Laser Automatic Switch-off
30s
Unit Automatic Switch-off
By default, 90s. User can set to 30s, 60s, or 300s
Continuous Measuring
Yes
Area
Yes
Volume
Yes
Pythagoras 2-Point
Yes
Endpiece to measure from
corners
3
Yes
Battery Life (3 x AAA)
Up to 3000 Measurements
(2500 with
; DW0165S & DW0330S)
Dimension (H x D x W)
4.72 x 1.91 x 1.02in (120 x 48.5 x 26mm)
Weight (with Batteries)
9.88oz (280g)
Storage Temperature Range
14° F ~ 140° F (-10° C ~ +60 C)
Operating Temperature Range
32° F ~ 104° F (0° C ~ +40° C)
1
Measuring Accuracy
depends on the current conditions:
• Under
favorable
conditions (good target surface and room temperature), up to 33ft
(10m).
• Under
unfavorable
conditions (bright sunlight, a very weak reflecting target surface, or
large temperature fluctuations), the error can increase by to ± 0.003 in/ft (± 0.25mm/m)
for distances over 33ft (10m).
2
Resolution
is the finest measurement you can see, 1/16" (1mm).
3
Flip open the
endpiece
at the bottom of the tool when you need to fit the tool into corners or
grooves that are not at 180° angles. If a corner is at 90°, the endpiece can be used to hold
the tool up against something.