Page 7 highlights
GENERAL INFORMATION EI30MH55GSA EI30MH55GBA EI30MH55GWA GROUNDING INSTRUCTIONS This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. WARNING: Improper use of the grounding plug can result in a risk of electric shock. Electrical Requirements The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG. The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more dedicated line, using a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood system mounting location. 3-Pronged Plug Grounded Receptacle Box Grounding Pin 3-Pronged Receptacle OVEN DIAGRAM 8 11 1 7 2 3 6 4 5 1. Oven door with see-through window. 2. Door hinges. 3. Oven lamp. It will light when oven is operating or door is open. 4. Door latches. The oven will not operate unless the door is securely closed. 5. One touch door open button 6. Auto-Touch control panel. 7. Timer display: Digital display, 99 minutes 00 seconds. 8. Ventilation openings. 9. Light Cover. 10. Grease filters. 11. Power supply cord 8 8 10 9 10