installation Requirements Electrical system requirements Electrical requirements for electric d_jer: CIRCUIT - individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit. POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current. with clothes dryers. For 3-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM. 4-WIRE POWER SUPPLY CORD KIT (not supplied) 4-wire receptacle (NEMA type 14-30R) The dryer MUST employ a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 4-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM. 3-WIRE POWER SUPPLY CORD KIT (not supplied) 3-wire receptacle (NEMA type 10-30R) The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp, with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position. GROUNDING CONNECTION - See "Grounding requirements" in Electrical installation section. Electrical requirements for gas d_jer: CIRCUIT - individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker. POWER SUPPLY - 2-wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current. POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire power cord. GROUNDING CONNECTION - See "Grounding requirements" in Electrical installation section. Grounding type wall receptacle Do not, under -'_ any circumstances, cut, remove, or bypass the grounding prong., Power cord with 3-prong grounded plug

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

installation
Requirements
Electrical
system
requirements
Electrical
requirements
for
electric
d_jer:
CIRCUIT - individual
30 amp. branch circuit
fused with 30 amp. time delay fuses or circuit
breakers. Use separately
fused circuits
for
washer and dryer. DO NOT operate a washer
and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire,
240 volt,
single phase, 60 Hz, Alternating
Current.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
3-wire
receptacle
(NEMA
type
10-30R)
The dryer MUST employ
a 3-conductor
power
supply
cord NEMA 10-30 type SRDT rated at
240 volt AC minimum,
30 amp, with 3 open
end spade lug connectors
with upturned
ends
or closed
loop connectors
and marked for use
with clothes dryers.
For 3-wire cord connection
instructions
see ELECTRICAL CONNECTIONS
FOR A 3-WIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
4-wire
receptacle
(NEMA
type
14-30R)
The dryer MUST employ a 4-conductor
power
supply cord NEMA 14-30 type SRDT or ST (as
required) rated at 240 volt AC minimum, 30 amp,
with 4 open end spade lug connectors
with
upturned ends or closed
loop connectors
and
marked for use with clothes dryers. For 4-wire
cord connection
instructions
see ELECTRICAL
CONNECTIONS
FOR A 4-WIRE SYSTEM.
OUTLET RECEPTACLE - NEMA 10-30R or NEMA
14-30R receptacle to be located so the power
supply cord is accessible
when the dryer is in the
installed position.
GROUNDING
CONNECTION
- See "Grounding
requirements"
in Electrical
installation
section.
Electrical
requirements
for
gas d_jer:
CIRCUIT -
individual,
properly polarized
and
grounded
15 amp. branch circuit
fused with 15
amp. time delay fuse or circuit
breaker.
POWER SUPPLY - 2-wire, with ground,
120 volt,
single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - The dryer is equipped
with a 120 volt 3-wire
power cord.
GROUNDING
CONNECTION
- See "Grounding
requirements"
in Electrical
installation
section.
Grounding type
wall receptacle
Do not, under
-'_
any circumstances,
cut, remove,
or bypass the
grounding
prong.,
Power cord with
3-prong
grounded plug