Electrolux EIGD55IKG Installation Instructions - Page 6
installation
UPC - 012505379710
View all Electrolux EIGD55IKG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
installation Requirements Exhaust system requirements, continued The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area. MAXIMUM LENGTH of 4" (10.2cm) Rigid Metal Duct Z VENT HOOD TYPE (Preferred) o E* 4" (10.2cm) Iouvered 2.5" (6.35cm) 0 125 ft. (38.10m) 110 ft. (33.53m) 1 115 ft. (35.05m) 100 ft. (30.48m) 2 105 ft. (32.00m) 90 ft. (27.43m) 3 95 ft. (28.96m) 80 ft. (24.38m) 4 85 ft. (25.91 m) 70 ft. (21.34m) MAXIMUM LENGTH of 4" (10.2cm)Semi-Rigid Metal Duct Z VENT HOOD TYPE (Preferred) o E* 4" (10.2cm) Iouvered 2.5" (6.35cm) 0 60 ft. (18.29m) 45 ft. (13.72m) 1 50 ft. (15.24m) 35 ft. (10.67m) 2 40 ft. (12.19m) 25 ft. (7.62m) 3 NOT RECOMMENDED Install male fittings in correct direction: In installations where the exhaust system is not described in the charts, the following method must be used to determine if the exhaust system is acceptable: CORRECT INCORRECT