TM-L90/TM-L90 Peeler Model Technical Reference Guide 2.8.1 Memory switches of TM-L90 In the following tables, "✓" shows that the setting can be set by the utility or the setting mode. Msw1 Msw Function 1-1 Transmission of Power-on notice 1-2 Receive buffer capacity 1-3 BUSY condition 1-4 Data processing for receive error 1-5 Automatic line feed 1-6 (Reserved) 1-7 #6 pin of RS-232 1-8 #25 pin of RS-232 Off Disabled On Enabled Initial Msw Setting Msw Setting setting utility Mode Off ✓ ✓ 4K bytes 45 bytes Off ✓ ✓ Receive Receive Off ✓ ✓ buffer full or buffer full Offline Replaced Ignored Off ✓ ✓ with "?" Disabled Enabled Off ✓ ✓ Fixed to Off Off Not used Used for reset Off ✓ ✓ Not used Used for reset Off ✓ ✓ [Msw1-4], [Msw1-7], [Msw1-8]: Valid only for serial interface [Msw1-5]: Valid only for parallel interface [Msw1-7], [Msw1-8]: Not available for TM-L90 4** models Msw2 Msw Function 2-1 (Reserved) 2-2 Autocutter function 2-3 (Reserved) to 2-8 Off On Fixed to On (Do not change) Disabled Enabled - - Initial Msw Setting Msw Setting setting utility Mode On On ✓ ✓ Off Setup 45