INSTALLATION INSTRUCTIONS EN Connecting dryer using 4-wire connection (must be used for mobile home installation) Note: Since January 1, 1996, the National Electrical Code requires that new constructions use a 4-wire connection to an electric dryer. A 4-wire cord must also be used where local codes do not permit grounding through the neutral. 3-wire connection is NOT for use on new construction. L1 N L2 Cover Green wire from power cord 3/4" Strain relief and bracket 4 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals with upturned ends (not supplied) 1 Turn off the circuit breaker(s) (30 amp) or remove the dryer's circuit fuse at the electrical box. 2 Be sure the dryer cord is unplugged from the wall receptacle. 3 Remove the power cord cover located at the upper back. 4 Remove green ground screw and retain for use in Step 7. Remove center screw (marked N) in terminal block. Remove and discard ground strap. 5 Install 3/4 in. UL-recognized strain relief to power cord entry hole. Bring power cord through strain relief and bracket. 6 Connect power cord as follows: z Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2). z Connect the neutral (white) line to the center of the terminal block (marked N). 7 Attach ground wire of power cord with the green ground screw (hole above strain relief bracket). Tighten all terminal block screws (3) securely. 8 Properly secure power cord to strain relief and bracket. 9 Reinstall the cover. IMPORTANT! Never leave the cover off of the terminal block. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

13
INSTALLATION INSTRUCTIONS
Connecting dryer using 4-wire connection (must be used for mobile home installation)
Note:
Since January 1, 1996, the National Electrical Code requires that new constructions use a
4-wire connection to an electric dryer. A 4-wire cord must also be used where local codes
do not permit grounding through the neutral. 3-wire connection is NOT for use on new
construction.
L1
N L2
Cover
Green wire from
power cord
3/4” Strain relief
and bracket
4 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use with
dryers and provided with closed loop or spade terminals with upturned ends (not supplied)
1
Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the
electrical box.
2
Be sure the dryer cord is unplugged from the wall receptacle.
3
Remove the power cord cover located at the upper back.
4
Remove green ground screw and retain for use in Step
7
. Remove center screw
(marked N) in terminal block. Remove and discard ground strap.
5
Install 3/4 in. UL-recognized strain relief to power cord entry hole. Bring power cord
through strain relief and bracket.
6
Connect power cord as follows:
z
Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2).
z
Connect the neutral (white) line to the center of the terminal block (marked N).
7
Attach ground wire of power cord with the green ground screw (hole above strain
relief bracket). Tighten all terminal block screws (3) securely.
8
Properly secure power cord to strain relief and bracket.
9
Reinstall the cover.
IMPORTANT!
Never leave the cover off of the terminal block.
EN