Fluke 1577 FE 1587-1577 Users Manual - Page 41

and 1587T Low-Pass Filter Voltage, 1577 Accuracy, Range, Resolution, Hz to 60 Hz, of Rdg + Digits

Page 41 highlights

Insulation Multimeters Electrical Specifications 1587 and 1587T Low-Pass Filter Voltage Range 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 Hz to 60 Hz ± (% of Rdg + Digits) + (1 % + 3) + (1 % + 3) + (1 % + 3) + (1 % + 3) + (2 % + 3) 60 Hz to 400 Hz ± (% of Rdg + Digits) + (2 % + 3) - (6 % - 3) + (2 % + 3) - (6 % - 3) + (2 % + 3) - (6 % - 3) + (2 % + 3) - (6 % - 3) + (2 % + 3) - (6 % - 3) 1577 Accuracy Range 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 Hz to 60 Hz ± (% of Rdg + Digits) + (2 % + 3) + (2 % + 3) + (2 % + 3) + (2 % + 3) + (2 % + 3) AC Conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 up to 500 V, decreasing linearly to crest factor

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Insulation Multimeters
Electrical Specifications
31
1587 and 1587T Low-Pass Filter Voltage
Range
Resolution
50 Hz to 60 Hz
±
(% of Rdg + Digits)
60 Hz to 400 Hz
±
(% of Rdg + Digits)
600.0 mV
0.1 mV
+
(1 % + 3)
+ (2 % + 3)
- (6 % - 3)
6.000 V
0.001 V
+
(1 % + 3)
+ (2 % + 3)
- (6 % - 3)
60.00 V
0.01 V
+
(1 % + 3)
+ (2 % + 3)
- (6 % - 3)
600.0 V
0.1 V
+
(1 % + 3)
+ (2 % + 3)
- (6 % - 3)
1000 V
1 V
+
(2 % + 3)
+ (2 % + 3)
- (6 % - 3)
1577 Accuracy
Range
Resolution
50 Hz to 60 Hz
±
(% of Rdg + Digits)
600.0 mV
0.1 mV
+
(2 % + 3)
6.000 V
0.001 V
+
(2 % + 3)
60.00 V
0.01 V
+
(2 % + 3)
600.0 V
0.1 V
+
(2 % + 3)
1000 V
1 V
+
(2 % + 3)
AC Conversion
....................................................
Inputs are ac-coupled and calibrated to the rms value of sine wave input. Conversions are
true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor
can be up to 3 up to 500 V, decreasing linearly to crest factor <= 1.5 at 1000 V. For
non-sinusoidal waveforms add
±
(2 % reading + 2 % FS) typical, for a crest factor up to 3.
Input Impedance
..................................................
10 M
(nominal), <100 pF, ac-coupled