Fluke 1577 FE 1587-1577 Users Manual - Page 47
Model 1587, Output Voltage, Display Range, Resolution, Test Current, Resistance Accuracy
View all Fluke 1577 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
Model 1587 Output Voltage 50 V (0 % to + 20 %) 100 V (0 % to + 20 %) 250 V (0 % to + 20 %) 500 V (0 % to + 20 %) 1000 V (0 % to + 20 %) Model 1577 Output Voltage 500 V (0 % to + 20 %) 1000 V (0 % to + 20 %) Display Range 0.01 to 6.00 MΩ 6.0 to 50.0 MΩ 0.01 to 6.00 MΩ 6.0 to 60.0 MΩ 60 to 100 MΩ 0.1 to 60.0 MΩ 60 to 250 MΩ 0.1 to 60.0 MΩ 60 to 500 MΩ 0.1 to 60.0 MΩ 60 to 600 MΩ 0.6 to 2.0 GΩ Display Range 0.1 to 60.0 MΩ 60 to 500 MΩ 0.1 to 60.0 MΩ Resolution 0.01 MΩ 0.1 MΩ 0.01 MΩ 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ 0.1 MΩ 1 MΩ 100 MΩ Resolution 0.1 MΩ 1 MΩ 0.1 MΩ Insulation Multimeters Electrical Specifications Test Current 1 mA @ 50 kΩ Resistance Accuracy ± (% of Rdg + Digits) ± (3 % + 5 counts) 1 mA @ 100 kΩ ± (3 % + 5 counts) 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ ± (1.5 % + 5 counts) ± (1.5 % + 5 counts) ± (1.5 % + 5 counts) ± (10 % + 3 counts) Test Current 1 mA @ 500 kΩ 1 mA @ 1 MΩ Resistance Accuracy ± (% of Rdg + Digits) ± (2.0 % + 5 counts) ± (2.0 % + 5 counts) 37