Installation Specification, NOTICE, Specification
UPC - 097564304156
View all Fujitsu 4340C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Installation Specification The following table lists the installation specifications of the scanner. Item Specification Dimensions (mm) (Without Hopper and Stacker) Depth 423 (16.6 in) Width 556 (21.9 in) Height 220 (8.7 in) Weight (kg) 15 (48.4 lb.) Voltage 100 to 120 VAC ± 10 % or 220 to 240 VAC ± 10 % Input power Phases Single-phase Frequency 50/60 ± 3 Hz Power consumption 125 VA or less Device status Operating Not operating Ambient condition Temperature 5 to 35 °C (41 to 95 °F) -20 to 60 °C (-4 to 140 °F) Humidity 20 to 80 % 8 to 95 % Heat capacity 110 kcal/H (442 BTU/H) Shipping Weight (kg) 19 (41.9Ib) Production Life 5 years or 2 million scans NOTICE The service life is estimated at 5 years after purchase or 2 million scans, whichever comes first. The cumulative number of scans are recorded by the Life Counter. For details on how to view the Life Counter display, refer to Chapter6 "Counter Display (page 6-2)". NOTICE Refer to the Cleaning and Maintenance guide for replacing the consumables. G 10-3