Fujitsu MJA2500BH Maintenance Manual - Page 92
BIST Active - Bidirectional, BIST Active - Bidirectional FIS layout, Table 5.4,
View all Fujitsu MJA2500BH manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
Interface 5.2.3.6 BIST Active - Bidirectional The BIST Active - Bidirectional FIS has the following layout: 33222222222211111111119876543210 1098765432109876543210 Reserved (0) Pattern definition R R R Reserved (0) FIS Type (58h) 0 TAS L F PRV 1 Data [31:24] Data [23:16] Data [23:16] Data [7:0] 2 Data [31:24] Data [23:16] Data [23:16] Data [7:0] Figure 5.8 BIST Active - Bidirectional FIS layout The BIST Active - Bidirectional FIS is used to set the receiver to Loop Back mode. This FIS can be sent by either the host system or device. The following combinations of pattern definitions are supported: Table 5.4 BIST combinations T A S L F P V SC Reg Contents - - - 1 - - 1 09h SATA Phy Analog Loopback Mode - - - 1 - - - 10h Far End Retimed Loopback Mode 1 1 - - - - - C0h No ALIGN Transmit_only Mode (Scramble ON) (*1) 1 1 1 - - - - E0h No ALIGN Transmit_only Mode (Scramble OFF) 1 1 - - - 1 - C4h No ALIGN Transmit_only with primitive Mode (Scramble ON) (*1) 1 1 1 - - 1 - E4h No ALIGN Transmit_only with primitive Mode (Scramble OFF) 1 80h ALIGN Transmit_only Mode (Scramble ON) (*1) 1 - 1 - - - - A0h ALIGN Transmit_only Mode (Scramble OFF) 1 - - - - 1 - 84h ALIGN Transmit_only with primitive Mode (Scramble ON) (*1) 1 - 1 - - 1 - A4h ALIGN Transmit_only with primitive Mode (Scramble OFF) 5-18 C141-E293