DISASSEMBLY INSTRUCTIONS IMPORTANT NOTES: UNIT MUST BE DISCONNECTED FROM ELECTRICAL OUTLET WHEN MAKING REPAIRS, REPLACEMENTS, ADJUSTMENTS AND CONTINUITY CHECKS. WAIT AT LEAST ONE MINUTE, UNTIL THE HIGH VOLTAGE CAPACITOR IN THE HIGH VOLTAGE POWER SUPPLY HAS FULLY DISCHARGED. THE CAPACITOR SHOULD BE DISCHARGED BY USING INSULATED WIRE - I.E. TEST PROBE CONNECTED TO 10K-OHM RESISTOR IN SERIES TO GROUND. WHEN RECONNECTING THE WIRE LEADS TO ANY PART, MAKE SURE THE WIRING CONNECTIONS AND LEAD COLORS ARE CORRECTLY MATCHED ACCORDING TO THE OVERALL CIRCUIT DIAGRAM. (ESPECIALLY SWITCHES AND HIGH VOLTAGE CIRCUIT.) A. REMOVING POWER AND CONTROL CIRCUIT BOARD (Figures 1, 2 and 3) (1) Disconnect power at the main fuse or circuit breaken, or pull the plug. Remove the top grille by removing the two screws that hold it in place. (2) Remove a screw securing the control panel assembly to the oven cavity. (3) Remove the control panel with pushing it upward. (4) Remove the six connectors (CN1, CN2, CN3, CN5, CN6, CN8) and wire leads (Relay2, Relay11) from the circuit board. Screw Control Panel (5) Remove 7 screws securing the circuit board. Circuit Board Figure 2 (6) Remove the FPC connector from the terminal socket following "HOW TO REMOVE THE FPC CONNECTOR" on the next page. (7) Remove the knob. (8) Remove the circuit board from the control bracket carefully. Control Bracket Power Transformer (CN3) (CN6) (Relay 11) (Relay 2) (CN8) (CN5) Figure 1 (CN2) (CN1) FPC Connector(S1) Circuit Board 7-4 Figure 3