GE JVM1790SK Service Manual - Page 25
Interlock Continuity Test
UPC - 084691123453
View all GE JVM1790SK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
INTERLOCK CONTINUITY TEST A. PRIMARY INTERLOCK SWITCH TEST When the door is opened slowly, an audible click should be heard at the same time or successively at intervals and the latches should activate the switches with an audible click. If the latches do not activate the switches when the door is closed, the switches should be a adjusted in accordance with the adjustment procedure. Disconnect the wire lead from the primary switch. Connect the ohmmeter leads to the common (COM) and normally open (NO) terminal of the switch. The meter should indicate an open circuit in the door open condition. When the door is closed, the meter should indicate a closed circuit. When the primary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch. B. SECONDARY INTERLOCK SWITCH TEST Disconnect the wire lead from the secondary switch. Connect the ohmmeter leads to the common (COM) and normally open (NO) terminals of the switch. The meter should indicate a open circuit in the door open condition. When the door is closed, meter should indicate an closed circuit. When the secondary switch operation is abnormal, make the necessary adjustment or replace the switch only with the same type of switch. C. MONITOR SWITCH TEST Disconnect the wire lead from the monitor switch. Connect the ohmmeter leads to the common (COM) and normally closed (NC) terminals of the switch. The meter should indicate closed circuit in the door open condition. When the door is closed, meter should indicate an open circuit. When the monitor switch operation is abnormal, replace with the same type of switch. NOTE: After repairing the door or the interlock system, it is necessary to do this continuity test before operating the oven. COMPONENTS SWITCHES (Wire leads removed) TEST PROCEDURE Check for continuity of the switch with an Ohm-meter RESULTS Door open Door closed Primary Switch NO COM Monitor Switch NC COM Secondary Switch NO COM NOTE: After checking for the continuity of switches, make sure that they are connected correctly. WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS. TYPE NO. SZM-V16-FA-63, VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH TYPE NO. SZM-V16-FA-62, VP-532A-OF OR V-5220Q FOR MONITOR SWITCH TYPE NO. SZM-V16-FA-63, VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH 7-14