Hayward ColorLogic 4.0 LED Pool Light 120v/50 ft. Cable Plastic ColorLogic-Ins - Page 5

Connect Ground Wire To Niche If Necessary, Mount The Light Fixture, Install Field-Installed Wiring

Page 5 highlights

Connect Ground Wire To Niche (If Necessary) If non-metallic conduit is used, connect the #8 AWG copper ground wire to the grounding connector inside the fixture housing (niche). This termination must be encapsulated using a listed potting compound* to a thickness of at least 1/8 inch (4 mm) in accordance with Article 680 of the NEC. * 3M Inc. Scotch Cast Wet Niche Potting Compound No. 2135 (UL File E130394) or equivalent. Mount The Light Fixture Coil up the extra cord and insert it in the fixture housing (niche) behind the light fixture. To mount the light fixture, insert the fixture into the niche with the mounting screw at the top (12 o'clock position). Place the bottom hook in first (6 o'clock position), then tilt the top of the fixture up and secure it with the mounting screw. Be sure the hook on the bottom catches on the niche. When removing the fixture from the niche, unscrew the mounting screw, tilt the top of the fixture out, and lift it up and out. NOTE: When installing the light into the Hayward SP0607U fixture housing, you must use the brass spacer (included). The mounting screw must pass through the spacer before threading into the mounting hole in the fixture housing. Install Field-Installed Wiring Run conduit from the junction box to the power supply, pool/spa controller, or switch box. Snake 3 wires (match to wire gauge of light cord, or larger) through the conduit from the junction box to the power supply, pool/spa controller, or switch box. If multiple lights are being installed, run additional conduit/wires from the junction box to the additional junction box(es). When wiring multiple lights to the same branch circuit, care should be taken to size the wiring adequately based on the total wattage of all lights connected to the circuit. Use wire nuts to connect the field-installed wiring to the light fixture cord in the junction box. Connect the ground wires to the ground terminal connections inside the junction box. 4 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Connect Ground Wire To Niche (If Necessary)
If non-metallic conduit is used, connect the #8 AWG copper ground wire to the grounding connector inside the fixture housing (niche). This termination must be
encapsulated using a listed potting compound* to a thickness of at least 1/8 inch (4 mm) in accordance with Article 680 of the NEC.
* 3M Inc. Scotch Cast Wet Niche Potting Compound No. 2135 (UL File E130394) or equivalent.
Mount The Light Fixture
Coil up the extra cord and insert it in the fixture housing (niche) behind the light fixture. To
mount the light fixture, insert the fixture into the niche with the mounting screw at the top
(12 o’clock position). Place the bottom hook in first (6 o’clock position), then tilt the top
of the fixture up and secure it with the mounting screw. Be sure the hook on the bottom
catches on the niche. When removing the fixture from the niche, unscrew the mounting
screw, tilt the top of the fixture out, and lift it up and out.
NOTE: When installing the light into the Hayward SP0607U fixture housing, you must use the
brass spacer (included). The mounting screw must pass through the spacer before thread-
ing into the mounting hole in the fixture housing.
Install Field-Installed Wiring
Run conduit from the junction box to the power supply, pool/spa controller, or
switch box. Snake 3 wires (match to wire gauge of light cord, or larger) through
the conduit from the junction box to the power supply, pool/spa controller, or
switch box. If multiple lights are being installed, run additional conduit/wires from
the junction box to the additional junction box(es). When wiring multiple lights to
the same branch circuit, care should be taken to size the wiring adequately based
on the total wattage of all lights connected to the circuit. Use wire nuts to connect
the field-installed wiring to the light fixture cord in the junction box. Connect the