HP 6100 HP 4x00/6x00/8x00 Enterprise Virtual Array User Guide (5697-0733, Marc - Page 119

Power specifications, Table 35 Power Data North America/Europe/Japan maximum configuration

Page 119 highlights

Table 33 Environmental specifications Operating Temperature Shipping Temperature Humidity Shipping Humidity Altitude Air Quality 50° to 95° F (10° to 35° C) - Reduce rating by 1° F for each 1000 ft. altitude (1.8° C/1,000 m) -40° to 150° F (-40° to 66° C) 10% to 90% non-condensing 5% to 90% non-condensing Up to 8,000 ft. (2,400 m) Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger Power specifications The input voltage is a function of the country-specific input voltage to Enterprise storage system rack power distribution units (PDUs). Table 34 (page 119) defines the AC input power available to the drive enclosure power supplies. CAUTION: The AC power distribution within a rack ensures balance to each PDA and reduces the possibility of an overload condition. Changing the cabling to or from a PDM could cause an overload condition. Table 34 Enterprise storage system AC input line voltages Specification AC Line Voltage AC Line Voltage-Japan AC Line Voltage-North America AC Line Voltage-Europe AC Line Frequency AC Line Voltage-Japan AC Line Voltage-North America AC Line Voltage-North America AC Line Voltage-Europe Minimal 60 Hz service 57 Hz 180 VAC 180 VAC 208 VAC 50 Hz service 47 Hz 180 VAC 190 VAC 200 VAC 208 VAC Nominal 60 Hz 202 VAC 208 VAC 240 VAC 50 Hz 202 VAC 220 VAC 230 VAC 240 VAC Maximum 63 Hz 220 VAC 220 VAC 254 VAC 53 Hz 220 VAC 235 VAC 244 VAC 254 VAC Table 35 Power Data (North America/Europe/Japan) maximum configuration AC plug type (quantity 2) Number of phases Rated current Nominal Line Voltage North America - 3 wire NEMA No. L6-30P, 30 amp (208 to 240V 50-60Hz 30A) Europe - 3 wire, 2 pole IEC 309, 30 amp, (220 to 240V 50Hz 32A) Single 17A @ 200V-240V AC, 60Hz total, 4.25 A per power cord North America - 208 or 230V Europe - 230V Japan - 206V Range Line Voltage Line Frequency 187 to 256V North America 60Hz, Europe 50Hz, Japan 50 or 60 Hz Storage system specifications 119

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185

Table 33 Environmental specifications
50° to 95° F (10° to 35° C) - Reduce rating by 1° F for each 1000 ft. altitude (1.8°
C/1,000 m)
Operating Temperature
-40° to 150° F (-40° to 66° C)
Shipping Temperature
10% to 90% non-condensing
Humidity
5% to 90% non-condensing
Shipping Humidity
Up to 8,000 ft. (2,400 m)
Altitude
Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger
Air Quality
Power specifications
The input voltage is a function of the country-specific input voltage to Enterprise storage system
rack power distribution units (PDUs).
Table 34 (page 119)
defines the AC input power available to
the drive enclosure power supplies.
CAUTION:
The AC power distribution within a rack ensures balance to each PDA and reduces
the possibility of an overload condition. Changing the cabling to or from a PDM could cause an
overload condition.
Table 34 Enterprise storage system AC input line voltages
Maximum
Nominal
Minimal
Specification
60 Hz service
63 Hz
60 Hz
57 Hz
AC Line Voltage
220 VAC
202 VAC
180 VAC
AC Line Voltage—Japan
220 VAC
208 VAC
180 VAC
AC Line Voltage–North America
254 VAC
240 VAC
208 VAC
AC Line Voltage–Europe
50 Hz service
53 Hz
50 Hz
47 Hz
AC Line Frequency
220 VAC
202 VAC
180 VAC
AC Line Voltage–Japan
235 VAC
220 VAC
190 VAC
AC Line Voltage–North America
244 VAC
230 VAC
200 VAC
AC Line Voltage–North America
254 VAC
240 VAC
208 VAC
AC Line Voltage–Europe
Table 35 Power Data (North America/Europe/Japan) maximum configuration
North America – 3 wire NEMA No. L6-30P, 30 amp (208 to 240V 50–60Hz 30A)
Europe – 3 wire, 2 pole IEC 309, 30 amp, (220 to 240V 50Hz 32A)
AC plug type (quantity 2)
Single
Number of phases
17A @ 200V-240V AC, 60Hz total, 4.25 A per power cord
Rated current
North America – 208 or 230V
Europe – 230V
Japan – 206V
Nominal Line Voltage
187 to 256V
Range Line Voltage
North America 60Hz, Europe 50Hz, Japan 50 or 60 Hz
Line Frequency
Storage system specifications
119