en.06 UNRECOVERABLE condition—No blowers installed, Temperature conditions
View all HP 6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 128 highlights
0.3.en.06 UNRECOVERABLE condition-No blowers installed NOTE: IMPORTANT When this condition exists there will be two error messages. The first message will be 0.3.en.05 and will identify the first blower. The second message will be 0.3.en.06 and will identify the second blower. The EMU cannot detect any installed blowers. Shutdown is imminent! The EMU will shut down the enclosure in seven minutes unless you correct the problem. This condition report remains active until you correct the problem or the EMU shuts down the power supplies, whichever occurs first. Complete the following procedure to correct this problem. 1. Record all six characters of the condition report. 2. Use the controller shutdown procedure to shut down the controllers. 3. Contact your authorized service representative. CAUTION: An automatic shutdown and possible data corruption may result if the blower is removed before a replacement is available. Temperature conditions The format of a temperature condition report is 0.4.en.ec, where: • 0.4. is the temperature sensor element type • en. is the two-character temperature sensor element • ec is the error code See Table 43 (page 128) to determine the location of each temperature sensor. Table 43 Temperature sensor element numbering Sensor 01. 02. 03. 04. 05. 06. 07. 08. 09. Sensor location Power Supply 1 Exhaust Power Supply 2 Exhaust EMU Drive Bay 1 Drive Bay 2 Drive Bay 3 Drive Bay 4 Drive Bay 5 Drive Bay 6 Sensor 10. 11. 12. 13. 14. 15. 16. 17. Sensor location Drive Bay 7 Drive Bay 8 Drive Bay 9 Drive Bay 10 Drive Bay 11 Drive Bay 12 Drive Bay 13 Drive Bay 14 The following sections list the temperature condition reports and the default temperature thresholds. Use HP Command View EVA to view the temperature sensor ranges for the disk drives, EMU, and power supplies. 0.4.en.01 NONCRITICAL condition-High temperature This condition report indicates that an element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. This condition report remains active until the problem is corrected. Complete the following procedure to correct this problem. 1. Record all six characters of the condition report. 2. Ensure that all elements are properly installed to maintain proper air flow. 128 EMU-generated condition reports