HP 8/20q HP StorageWorks 8/20q Fibre Channel Switch installation and reference - Page 45

Excessive port errors

Page 45 highlights

3. Display the fabric domain IDs using the show domains CLI command or by selecting the QuickTools Switch tab, Summary icon. Are all domain IDs in the fabric unique? • Yes-Continue. • No-Correct the domain IDs on the offending switches using the set config switch CLI command or the QuickTools Switch Properties dialog. Reset the port. If the condition remains, continue. 4. Compare the RA_TOV and ED_TOV timeout values for all switches in the fabric using the show config switch CLI command or by selecting the QuickTools Switch tab, Advanced icon. Is each timeout value the same on every switch? • Yes-Continue. • No-Correct the timeout values on the offending switches using the set config switch CLI command or selecting Switch>Advanced Switch Properties in QuickTools. Reset the port. If the condition remains, continue. 5. Display the active zone set on each switch using the zoning active CLI command or by selecting the QuickTools Active Zoneset tab. Compare the zone membership between the two active zone sets. Are they the same? • Yes-Contact your authorized maintenance provider. • No-Deactivate one of the active zone sets or edit the conflicting zones so that their membership is the same, then reset the port. If the condition remains, contact your authorized maintenance provider. NOTE: E_Port isolation can be caused by merging two fabrics whose active zone sets have two zones with the same name, but different membership. Excessive port errors The switch can monitor a set of port errors and generate alarms based on user-defined sample windows and thresholds. These port errors include the following: • Cyclic Redundancy Check (CRC) errors • Decode errors • ISL connection count • Device login errors • Device logout errors • Loss-of-signal errors Port threshold alarm monitoring is disabled by default. For information about managing port threshold alarms, see the HP StorageWorks 8/20q Fibre Channel Switch command line interface guide. If the count for any of these errors exceeds the rising trigger for three consecutive sample windows, the switch generates an alarm and disables the affected port, changing its operational state to "down." Port errors can be caused by the following: • Triggers are too low or the sample window is too small • Faulty Fibre Channel port cable • Faulty SFP • Faulty port • Faulty device or HBA 8/20q Fibre Channel Switch installation and reference guide 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

8/20q Fibre Channel Switch installation and reference guide
45
3.
Display the fabric domain IDs using the
show domains
CLI command or by selecting the QuickTools
Switch
tab,
Summary
icon. Are all domain IDs in the fabric unique?
Yes—Continue.
No—Correct the domain IDs on the offending switches using the
set config switch
CLI
command or the QuickTools Switch Properties dialog. Reset the port. If the condition remains,
continue.
4.
Compare the RA_TOV and ED_TOV timeout values for all switches in the fabric using the
show
config switch
CLI command or by selecting the QuickTools
Switch
tab,
Advanced
icon. Is each
timeout value the same on every switch?
Yes—Continue.
No—Correct the timeout values on the offending switches using the
set config switch
CLI
command or selecting
Switch>Advanced Switch Properties
in QuickTools. Reset the port. If the
condition remains, continue.
5.
Display the active zone set on each switch using the
zoning active
CLI command or by selecting
the QuickTools
Active Zoneset
tab. Compare the zone membership between the two active zone sets.
Are they the same?
Yes—Contact your authorized maintenance provider.
No—Deactivate one of the active zone sets or edit the conflicting zones so that their membership is
the same, then reset the port. If the condition remains, contact your authorized maintenance
provider.
NOTE:
E_Port isolation can be caused by merging two fabrics whose active zone sets have two zones
with the same name, but different membership.
Excessive port errors
The switch can monitor a set of port errors and generate alarms based on user-defined sample windows
and thresholds. These port errors include the following:
Cyclic Redundancy Check (CRC) errors
Decode errors
ISL connection count
Device login errors
Device logout errors
Loss-of-signal errors
Port threshold alarm monitoring is disabled by default. For information about managing port threshold
alarms, see the
HP StorageWorks 8/20q Fibre Channel Switch command line interface guide
.
If the count for any of these errors exceeds the rising trigger for three consecutive sample windows, the
switch generates an alarm and disables the affected port, changing its operational state to “down.” Port
errors can be caused by the following:
Triggers are too low or the sample window is too small
Faulty Fibre Channel port cable
Faulty SFP
Faulty port
Faulty device or HBA