HP BladeSystem c3000 HP BladeSystem Deployment Guide for Solutions with 6Gb SA - Page 61

SAS BL Switch are displayed as Device ID on the Switch Port Mapping in Onboard, HP SSA

Page 61 highlights

13. Configure the MDS600 or D6000 storage enclosure. If not included in your solution, proceed to the next step. a. Obtain and record the WWID of each MDS600 or D6000 I/O module in the provided spaces in "MDS600 and D6000 storage enclosure worksheet" (page 106). b. Obtain and record the SAS WWN of all P711m/P712m ports on all server blades that will access the MDS600 or D6000 storage in the provided spaces in "Server and P711m, P712m, and P721m/P731m controller worksheet" (page 102). The WWNs of all P711m, P712m, or P721m/P731m ports connected to each HP 6Gb SAS BL Switch are displayed as "Device ID" on the Switch Port Mapping page in Onboard Administrator. (See the HP Onboard Administrator user guide.) c. From each server assigned a drive-bay zone group, create arrays and LUNs using the HP SSA, ACU or ACU CLI. ("ACU" in the Configuring Arrays on HP Smart Array Controllers Reference Guide) For information on the HP SSA, see the HP Smart Storage Administrator User Guide. 14. Configure the D2600/D2700 storage enclosure. If not included in your solution, proceed to the next step. a. Obtain and record the WWID of each D2600/D2700 I/O module in the provided spaces in "HP D2600/D2700 storage enclosure worksheet" (page 107). b. Obtain and record the SAS WWN of all P711m, P712m, or P721m/P731m ports on all server blades that will access the D2600/D2700 storage in the provided spaces in "Server and P711m, P712m, and P721m/P731m controller worksheet" (page 102). These WWN are used in the ACU when granting hosts access to the storage. The WWNs of all P711m, P712m, or P721m/P731m ports connected to each 6Gb SAS BL switch are displayed as "Device ID" on the Switch Port Mapping page in Onboard Administrator. (HP Onboard Administrator user guide) c. From each server assigned a drive-bay zone group, create arrays and LUNs using the HP SSA, ACU or ACU CLI. (See "ACU" in the Configuring Arrays on HP Smart Array Controllers Reference Guide.) 15. The basic steps of installing the BladeSystem solution are complete. Additional configuration steps may include: • If the MSA is used as a boot device for server blades, configure the server blades properly and then install the operating system. For information, see Booting from shared storage with direct connect SAS storage for HP BladeSystem and HP MSA2012sa on the P2000 G3 MSA Systems website. • Complete network setup. • Install software applications. • Set up and configure clusters. • Confirm multipathing software setup and configuration. • Connect SAS cables from the switch to the Tape Library or Autoloader. For more information about cabling Tape Libraries and Autoloaders, see "Tape library standard cabling" (page 96). Installation steps 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111

13.
Configure the MDS600 or D6000 storage enclosure. If not included in your solution, proceed
to the next step.
a.
Obtain and record the WWID of each MDS600 or D6000 I/O module in the provided
spaces in
“MDS600 and D6000 storage enclosure worksheet” (page 106)
.
b.
Obtain and record the SAS WWN of all P711m/P712m ports on all server blades that
will access the MDS600 or D6000 storage in the provided spaces in
“Server and P711m,
P712m, and P721m/P731m controller worksheet” (page 102)
.
The WWNs of all P711m, P712m, or P721m/P731m ports connected to each HP 6Gb
SAS BL Switch are displayed as “Device ID” on the Switch Port Mapping page in Onboard
Administrator. (See the
HP Onboard Administrator user guide
.)
c.
From each server assigned a drive-bay zone group, create arrays and LUNs using the
HP SSA, ACU or ACU CLI. (“ACU” in the
Configuring Arrays on HP Smart Array
Controllers Reference Guide
)
For information on the HP SSA, see the
HP Smart Storage Administrator User Guide
.
14. Configure the D2600/D2700 storage enclosure. If not included in your solution, proceed to
the next step.
a.
Obtain and record the WWID of each D2600/D2700 I/O module in the provided
spaces in
“HP D2600/D2700 storage enclosure worksheet” (page 107)
.
b.
Obtain and record the SAS WWN of all P711m, P712m, or P721m/P731m ports on
all server blades that will access the D2600/D2700 storage in the provided spaces in
“Server and P711m, P712m, and P721m/P731m controller worksheet” (page 102)
. These
WWN are used in the ACU when granting hosts access to the storage.
The WWNs of all P711m, P712m, or P721m/P731m ports connected to each 6Gb SAS
BL switch are displayed as “Device ID” on the Switch Port Mapping page in Onboard
Administrator. (
HP Onboard Administrator user guide
)
c.
From each server assigned a drive-bay zone group, create arrays and LUNs using the
HP SSA, ACU or ACU CLI. (See “ACU” in the
Configuring Arrays on HP Smart Array
Controllers Reference Guide
.)
15.
The basic steps of installing the BladeSystem solution are complete. Additional configuration
steps may include:
If the MSA is used as a boot device for server blades, configure the server blades properly
and then install the operating system. For information, see
Booting from shared storage
with direct connect SAS storage for HP BladeSystem and HP MSA2012sa
on the P2000
G3 MSA Systems website.
Complete network setup.
Install software applications.
Set up and configure clusters.
Confirm multipathing software setup and configuration.
Connect SAS cables from the switch to the Tape Library or Autoloader. For more
information about cabling Tape Libraries and Autoloaders, see
“Tape library standard
cabling” (page 96)
.
Installation steps
61