HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 19

LUNs in DCFM., only--no other checks are performed.

Page 19 highlights

Closed defect summary Solution Device Connectivity:Linux -3 of the results display nl "Index 0". Symptom-Three of the results displayed in the results dialog have "Index 0" displayed. The checks were for Device port check and Zone configuration. Fixed in DCFM 10.1.0 Tape Volume Label is not being displayed for tape LUNs in DCFM. Symptom-Tape Volume Label column does not display any data. Fixed in DCFM 10.1.0 DCFM causing many issues when a fabric is managed with a large zone DB. Symptom-When a user launches the Zoning dialog for a large zone DB (1MB), the dialog takes a long time and many zoning operations fail in the Zoning dialogue. Fixed in DCFM 10.1.0 Workaround-Manage large zone DB from fabric using CLI. Importing invalid zone DB xml file from Zoning dialog not showing validation error. Symptom-When a user imports an invalid xml file, no warning message appears from the Zoning dialog and nothing is imported to repository. Fixed in DCFM 10.1.0 Workaround-Verify and validate zone DB xml file manually before importing to offline repository. WebTools fails to launch for a switch running FOS V6.1.1. Symptom-Trying to launch WebTools page for a switch running FOS 6.1.1 may fail after a successful first launch. Fixed in DCFM 10.1.0 Device Connectivity: Only LSAN check is done for certain ports added through "Add detached". Symptom-The result dialog shows the LSAN check only--no other checks are performed. Fixed in DCFM 10.1.0 There is no warning message displayed when trying to close an unsaved PDCM configuration. Symptom-When a user has one or more unsaved configurations, and he clicks 'Close', the PDCM dialog closes without warning that the uncommitted changes will be lost. Fixed in DCFM 10.1.0 Config names edit WWN does not change WWN but adds an unnamed WWN. Symptom-Changing a name assignment by editing the WWN in the Configure-Names dialog does not work. It will leave the original Name - WWN pair in the dialog and will add an unnamed WWN to the All WWNs table. Fixed in DCFM 10.1.0 Workaround-First, remove this name. Then if it is an already discovered WWN you wish to name, find it in the All WWNs list, and then edit the Name field. If it is an undiscovered device, then add the Name and WWN as a detached WWN. HP StorageWorks B-series Data Center Fabric Manager Enterprise 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

Solution
Closed defect summary
Fixed in DCFM 10.1.0
Device Connectivity:Linux -3 of the results display
nl
"Index 0”.
Symptom—Three of the results displayed in the results
dialog have "Index 0” displayed. The checks were for
Device port check and Zone configuration.
Fixed in DCFM 10.1.0
Tape Volume Label is not being displayed for tape
LUNs in DCFM.
Symptom—Tape Volume Label column does not
display any data.
Fixed in DCFM 10.1.0
Workaround—Manage large zone DB from fabric
using CLI.
DCFM causing many issues when a fabric is managed
with a large zone DB.
Symptom—When a user launches the Zoning dialog
for a large zone DB (1MB), the dialog takes a long
time and many zoning operations fail in the Zoning
dialogue.
Fixed in DCFM 10.1.0
Workaround—Verify and validate zone DB xml file
manually before importing to offline repository.
Importing invalid zone DB xml file from Zoning dialog
not showing validation error.
Symptom—When a user imports an invalid xml file,
no warning message appears from the Zoning dialog
and nothing is imported to repository.
Fixed in DCFM 10.1.0
WebTools fails to launch for a switch running FOS
V6.1.1.
Symptom—Trying to launch WebTools page for a
switch running FOS 6.1.1 may fail after a successful
first launch.
Fixed in DCFM 10.1.0
Device Connectivity: Only LSAN check is done for
certain ports added through “Add detached”.
Symptom—The result dialog shows the LSAN check
only—-no other checks are performed.
Fixed in DCFM 10.1.0
There is no warning message displayed when trying
to close an unsaved PDCM configuration.
Symptom—When a user has one or more unsaved
configurations, and he clicks 'Close', the PDCM dialog
closes without warning that the uncommitted changes
will be lost.
Fixed in DCFM 10.1.0
Workaround—First, remove this name. Then if it is an
already discovered WWN you wish to name, find it
in the All WWNs list, and then edit the Name field.
If it is an undiscovered device, then add the Name
and WWN as a detached WWN.
Config names edit WWN does not change WWN
but adds an unnamed WWN.
Symptom—Changing a name assignment by editing
the WWN in the Configure-Names dialog does not
work. It will leave the original Name - WWN pair in
the dialog and will add an unnamed WWN to the All
WWNs table.
HP StorageWorks B-series Data Center Fabric Manager Enterprise
19