HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 19
LUNs in DCFM., only--no other checks are performed.
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Closed defect summary Solution Device Connectivity:Linux -3 of the results display nl "Index 0". Symptom-Three of the results displayed in the results dialog have "Index 0" displayed. The checks were for Device port check and Zone configuration. Fixed in DCFM 10.1.0 Tape Volume Label is not being displayed for tape LUNs in DCFM. Symptom-Tape Volume Label column does not display any data. Fixed in DCFM 10.1.0 DCFM causing many issues when a fabric is managed with a large zone DB. Symptom-When a user launches the Zoning dialog for a large zone DB (1MB), the dialog takes a long time and many zoning operations fail in the Zoning dialogue. Fixed in DCFM 10.1.0 Workaround-Manage large zone DB from fabric using CLI. Importing invalid zone DB xml file from Zoning dialog not showing validation error. Symptom-When a user imports an invalid xml file, no warning message appears from the Zoning dialog and nothing is imported to repository. Fixed in DCFM 10.1.0 Workaround-Verify and validate zone DB xml file manually before importing to offline repository. WebTools fails to launch for a switch running FOS V6.1.1. Symptom-Trying to launch WebTools page for a switch running FOS 6.1.1 may fail after a successful first launch. Fixed in DCFM 10.1.0 Device Connectivity: Only LSAN check is done for certain ports added through "Add detached". Symptom-The result dialog shows the LSAN check only--no other checks are performed. Fixed in DCFM 10.1.0 There is no warning message displayed when trying to close an unsaved PDCM configuration. Symptom-When a user has one or more unsaved configurations, and he clicks 'Close', the PDCM dialog closes without warning that the uncommitted changes will be lost. Fixed in DCFM 10.1.0 Config names edit WWN does not change WWN but adds an unnamed WWN. Symptom-Changing a name assignment by editing the WWN in the Configure-Names dialog does not work. It will leave the original Name - WWN pair in the dialog and will add an unnamed WWN to the All WWNs table. Fixed in DCFM 10.1.0 Workaround-First, remove this name. Then if it is an already discovered WWN you wish to name, find it in the All WWNs list, and then edit the Name field. If it is an undiscovered device, then add the Name and WWN as a detached WWN. HP StorageWorks B-series Data Center Fabric Manager Enterprise 19