HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 38

Create View dialog., Disable VF

Page 38 highlights

Closed defect summary Solution Files loaded in the firmware library of M-EOS Element Manager appear to be lost after migration from EFCM V9.7.x, but the files were actually imported to the install directory/data/eos/em/_Raw/firmware file folder. Fixed in DCFM 10.1.4 nl Workaround prior to this upgrade: Manually load the firmware file after migration. Very rarely, with a cascaded FICON configuration, the FICON Troubleshooting Wizard window does not show all switches or provide information in the error message box. Fixed in DCFM 10.1.4 After fabrics are discovered, ISLs disappear when a monitor or unmonitor Fixed in DCFM 10.1.4 operation is performed. In an M-EOS environment, if you select a different paddle (group of ports) Fixed in DCFM 10.1.4 in Line Module view, the Hardware/FRU view does not update to show the change, and you cannot see the ports on the selected Line module. After stopping services in the Server Management Console (SMC), the Fixed in DCFM 10.1.4 status bar does not indicate the same service status as the Services tab. ISL disappears in the Topology when the Seed Switch is changed from the switch running FOS 6.1 or earlier to a Non Default Logical Switch. Fixed in DCFM 10.1.4 On the HP StorageWorks 8/80 SAN Switch, four logical switches are allowed. If you have configured four logical switches, and you use the Logical Switches window to delete a switch and then create a new one, when you click OK to process the edits, the old logical switch is deleted, but the new one is not created. An error message appears, indicating that the maximum number of logical switches are present on the switch. Fixed in DCFM 10.1.4 Internal errors and slow response times occur on the host server during DCFM installation. Database timeouts are written to the log. Fixed in DCFM 10.1.4 Real-time performance graphs are not displayed for some end-to-end monitors and the following error message is written to the log Switch null in fabric has been removed from discovery. Real time performance data not available. Fixed in DCFM 10.1.4 Selecting Disable VF from the chassis group without discovering the default Fixed in DCFM 10.1.4 switch does not disable the VF; an error message appears. The Create Meta-SAN View menu option is not available when right-clicking a backbone fabric. Fixed in DCFM 10.1.4 nl Workaround prior to this upgrade: The functionality is available in the Create View dialog. 38

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

Solution
Closed defect summary
Fixed in DCFM 10.1.4
nl
Workaround prior to this upgrade:
Manually load the firmware file
after migration.
Files loaded in the firmware library of M-EOS Element Manager appear
to be lost after migration from EFCM V9.7.x, but the files were actually
imported to the
install directory
/data/eos/em/_Raw/firmware
file
folder.
Fixed in DCFM 10.1.4
Very rarely, with a cascaded FICON configuration, the FICON
Troubleshooting Wizard window does not show all switches or provide
information in the error message box.
Fixed in DCFM 10.1.4
After fabrics are discovered, ISLs disappear when a monitor or unmonitor
operation is performed.
Fixed in DCFM 10.1.4
In an M-EOS environment, if you select a different paddle (group of ports)
in Line Module view, the Hardware/FRU view does not update to show
the change, and you cannot see the ports on the selected Line module.
Fixed in DCFM 10.1.4
After stopping services in the Server Management Console (SMC), the
status bar does not indicate the same service status as the Services tab.
Fixed in DCFM 10.1.4
ISL disappears in the Topology when the Seed Switch is changed from
the switch running FOS 6.1 or earlier to a Non Default Logical Switch.
Fixed in DCFM 10.1.4
On the HP StorageWorks 8/80 SAN Switch, four logical switches are
allowed. If you have configured four logical switches, and you use the
Logical Switches window to delete a switch and then create a new one,
when you click
OK
to process the edits, the old logical switch is deleted,
but the new one is not created. An error message appears, indicating
that the maximum number of logical switches are present on the switch.
Fixed in DCFM 10.1.4
Internal errors and slow response times occur on the host server during
DCFM installation. Database timeouts are written to the log.
Fixed in DCFM 10.1.4
Real-time performance graphs are not displayed for some end-to-end
monitors and the following error message is written to the log
Switch
null in fabric has been removed from discovery. Real
time performance data not available
.
Fixed in DCFM 10.1.4
Selecting
Disable VF
from the chassis group without discovering the default
switch does not disable the VF; an error message appears.
Fixed in DCFM 10.1.4
nl
Workaround prior to this upgrade:
The functionality is available in the
Create View dialog.
The Create Meta-SAN View menu option is not available when
right-clicking a backbone fabric.
38