HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Enterpris - Page 35
DCFM 10.1.3 fixes, lists defects closed in the DCFM 10.1.3 release.
![]() |
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Closed defect summary Solution Read-only (RO) privileges for storage encryption configuration Fixed in DCFM 10.1.2 enables the user to remove a smart card entry. A user without Storage Encryption configuration privileges is Fixed in DCFM 10.1.2 able to add targets. DCFM 10.1.3 fixes Table 5 lists defects closed in the DCFM 10.1.3 release. Table 5 DCFM 10.1.3 closed defects Closed defect summary Solution Email notifications are not generated for triggered events in DCFM 10.1.2 Fixed in DCFM 10.1.3 or earlier, resulting in delayed notification of changes in the DCFM server. The properties dialog is blank for an HBA with virtual tag connected to a Fixed in DCFM 10.1.3 switch configured as an Access Gateway, and the HBA is not displayed in the topology. From the topology view, if you right-click and then select the Accept Fixed in DCFM 10.1.3 Changes option, any switches selected for removal are removed, but any devices selected for removal are not removed. When a copy of online database is saved from one fabric and then nl activated in another fabric, DCFM activates the zone set on the wrong fabric. Fixed in DCFM 10.1.3 The LSAN Zoning Activation Dialog function removes TI zones present in the fabric. nl Symptom-TI zones are missing after activating an LSAN zone. Fixed in DCFM 10.1.3 After migrating from DCFM 10.0.2, the call home status is displayed as Fixed in DCFM 10.1.3 disabled in the Advanced Call Home (ACH) dialog for M-EOS switches, even though it is enabled in the Element Manager. The user cannot disable Virtual Fabrics (VF) after all logical switches have Fixed in DCFM 10.1.3 been deleted. An Encryption Group that was created on an HP StorageWorks DC04 SAN Director without an HP StorageWorks DC Switch encryption blade resident in the chassis remains after a delete operation. Multiple delete commands are required to delete the Encryption Group. Fixed in DCFM 10.1.3 Using the Switch tab of the New Logical Fabric Template dialog to set a Fixed in DCFM 10.1.3 name fails to set the name to the switch. DCFM inappropriately allows a user to activate a new configuration or to edit the active configuration if the default zone is set to all access without an active zone configuration. However, Prohibit Dynamic Connectivity Mask (PDCM) will work only when there is an active zone configuration in the fabric. When the user tries to activate a new configuration or to edit the active configuration, it should be allowed only when there is an active zone configuration. Fixed in DCFM 10.1.3 HP StorageWorks B-series Data Center Fabric Manager Enterprise 35
![](/manual_guide/products/hewlettpackard-brocade-812c-hp-storageworks-bseries-data-center-fabric-manager-enterprise-1014-release-notes-56970085-2009-includes-101x-versions-131c595/35.png)