Closed defect summary Solution Remote client cannot be used when a server has client viewing on a second screen. Symptom-Remote client will appear off the screen. Fixed in DCFM 10.1.0 Workaround-At the server, move the client to the primary screen and close the client. Download the remote client again. ISLs not showing. Symptom-If the user moved ISLs between HP StorageWorks 8/80 SAN Switch and HP StorageWorks DC SAN Director to HP StorageWorks 4/256 Director so that they are between HP StorageWorks 8/80 SAN Switch to HP StorageWorks 4/256 Director, and then waited 20 minutes, the display still shows no ISLs between HP StorageWorks 8/80 SAN Switch and HP StorageWorks 4/256 Director. Fixed in DCFM 10.1.0 The title bar for online help is incorrect. Fixed in DCFM 10.1.0 Syslog received from forwarder but not showing in the syslog std or other port. Symptom-Cannot see Syslog events when forwarded from a syslog server that does not forward with the original IP address as the source address. Fixed in DCFM 10.1.0 Workaround-Use a syslog server that forwards syslogs using the original message's IP. Sort on port number not working properly. Order is 1, 10, 11, ... 19, 2, 20, 21. Only trunk master ISL is displayed in Connectivity Properties window. Timeout issue while saving zones in Interopmode 2. Symptom-When saving zones to a fabric in Interopmode 2, the operation may fail with an error message indicating HTTP timeout. Fixed in DCFM 10.1.0 Fixed in DCFM 10.1.0 Fixed in DCFM 10.1.0 Traps are not received if host name of the DCFM server is configured in the switch as trap recipient. Symptom-User will not receive any events from the switch. Fixed in DCFM 10.1.0 Workaround-Use IP address instead of host name for registering DCFM server as trap recipient. Master log is filling so quickly with log messages it is Fixed in DCFM 10.1.0 difficult to see errors. Not getting manageability of M-EOS switches (M6140 Fixed in DCFM 10.1.0 and Mi10K). Accept Change option does not prompt when a switch is missing from a fabric. Symptom-Accept Change option does not prompt the user when a switch is removed from the fabric. When accepting a fabric change, there is no warning informing the operator that switches will be dropped. Fixed in DCFM 10.1.0 HP StorageWorks B-series Data Center Fabric Manager Enterprise 27