Table 6-1 POST numeric codes and text messages (continued) Control panel message Description Recommended action 2E5-ECC Memory Module Detected on Unsupported Platform Recently added memory modules support ECC memory error correction. 1. If additional memory was recently added, remove it to see if the problem remains. 2. Check product documentation for memory support information. 2E6-Memory Not Configured Correctly for Proper MEBx Execution DIMM1 is not installed. Be sure that a memory module is in the DIMM1 socket and that it is properly seated. 300-Configuration Change Warning A change in storage configuration has been detected (see the Boot Options menu in BIOS Setup to enable this feature). Either the installed hardware has changed, storage or firmware mode might have been changed, or a storage device might have failed to respond. If no changes were made before this warning, check that the drives are connected properly to power cables and system board. User Diagnostics (f2 during boot-up) might help identify any problem with specific devices. 301-Hard Disk 1: SMART Hard Drive Detects Imminent Failure Hard drive will soon fail. (Some hard 1. drives have a hard drive firmware patch that will fix an erroneous error message.) Determine whether hard drive is giving correct error message. Run the Drive Protection System test under using F2 Diagnostics when booting the computer. 2. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) 3. Back up contents and replace hard drive. 302-Hard Disk 2: SMART Hard Drive Detects Imminent Failure Hard drive will soon fail. (Some hard 1. drives have a hard drive firmware patch that will fix an erroneous error message.) Determine whether hard drive is giving correct error message. Run the Drive Protection System test under using F2 Diagnostics when booting the computer. 2. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) 3. Back up contents and replace hard drive. 309 - 30C: Hard Disk 3-6: SMART Hard Drive Detects Imminent Failure Hard drive will soon fail. (Some hard 1. drives have a hard drive firmware patch that will fix an erroneous error message.) Determine whether hard drive is giving correct error message. Run the Drive Protection System test under using F2 Diagnostics when booting the computer. 2. Apply hard drive firmware patch if applicable. (Available at http://www.hp.com/support.) 3. Back up contents and replace hard drive. 3F0-Boot Device Not Found Boot device not found. Insert boot device or load operating system. POST numeric codes and text messages 83