From Print Care, run the, Force Leveling Calibration, BypassTableTopic > crJosActive, False
View all HP Indigo 30000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
5. Check the JOS components using the Print Care tests: ● Use Print Care to make sure that the cams are working correctly. ● Visually inspect the cams. Make sure they are fully connected to the motor axle. ● Visually inspect the flag. Make sure it is connected properly. Figure 5-1 Motor and flag area 6. At the molex connector, make sure that all of the pins are in place. Figure 5-2 Molex connector 7. Verify that the molex connector is not broken. 8. From Print Care, run the Force Leveling Calibration wizard. 9. In Systab, check the bypass statuses: ● Make sure that BypassTableTopic > crJosActive is False. ● Make sure that BypassTableTopic > crJosCalibration is False. ● Make sure that BypassTableTopic > crJosJumps is False. 10. Check the charge roller wiring at the press side: ● Check charge roller engage side - Wire W137. Troubleshooting the charge roller leveling failure - mechanical problem 23