HP Indigo W7250 Strain Gauge Second Transfer Measurement Service and Troublesh - Page 12
PrintCare wizard, Component Calibrations, Second Transfer Strain Gauge Calibration, For example
![]() |
View all HP Indigo W7250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
For example, the value 64.43 should replace the default value in the Systab to 6443 PrintCare wizard The 2nd transfer wizard is accessed through the PrC: Maintenance > Component calibration > Web Impression engage system. There are two wizards: ● Automatic: Second transfer strain gauge adjustment wizard ● Mechanical: Impression engage calibration wizard Figure 2-13 Component Calibrations NOTE: There are no UI or PLC strain gauge errors. Figure 2-14 Second Transfer Strain Gauge Calibration 10 Chapter 2 Introduction
![](/manual_guide/products/hewlettpackard-indigo-ws6000-strain-gauge-transfer-measurement-service-troubleshooting-ca39307540-rev-01-840471e/12.png)
For example, the value 64.43 should replace the default value in the Systab to 6443
PrintCare wizard
The 2nd transfer wizard is accessed through the PrC: Maintenance > Component calibration > Web
Impression engage system. There are two wizards:
●
Automatic: Second transfer strain gauge adjustment wizard
●
Mechanical: Impression engage calibration wizard
Figure 2-13
Component Calibrations
NOTE:
There are no UI or PLC strain gauge errors.
Figure 2-14
Second Transfer Strain Gauge Calibration
10
Chapter 2
Introduction