HP Indigo W7250 Strain Gauge Second Transfer Measurement Service and Troublesh - Page 13
Troubleshooting, Replace SGA board.
![]() |
View all HP Indigo W7250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Troubleshooting Troubleshoot the second transfer measurement strain gauget. Zero reading in 2nd Transfer Wizard In case of "0" reading at the 2nd transfer wizard, check the following ● Wiring between: J54 at the EC to the connectors/pins at the drivers ● Wiring between: SGA board all the way to the drivers. ● 5V supplied to the SGA board from U3. ● Replace SGA board. ● Check parameter 7.02 for reading Torque bushing Loss of 2nd transfer can happen if the torque bushings open. The torque should be 25 nm Figure 2-15 Torque bushings Troubleshooting 11
![](/manual_guide/products/hewlettpackard-indigo-ws6000-strain-gauge-transfer-measurement-service-troubleshooting-ca39307540-rev-01-840471e/13.png)
Troubleshooting
Troubleshoot the second transfer measurement strain gauget.
Zero reading in 2nd Transfer Wizard
In case of “0” reading at the 2nd transfer wizard, check the following
●
Wiring between: J54 at the EC to the connectors/pins at the drivers
●
Wiring between: SGA board all the way to the drivers.
●
5V supplied to the SGA board from U3.
●
Replace SGA board.
●
Check parameter 7.02 for reading
Torque bushing
Loss of 2nd transfer can happen if the torque bushings open. The torque should be 25 nm
Figure 2-15
Torque bushings
Troubleshooting
11