Port mapping For detailed port mapping information, see the HP BladeSystem Enclosure Quick Setup Guide or the HP BladeSystem Enclosure Setup and Installation Guide on the HP website (http://www.hp.com/go/bladesystem/documentation). Dual pass-thru modules In a dual pass-thru module configuration, two pass-thru modules in the HP BladeSystem c7000 Enclosure provide redundant paths to the network ports on the server blades. Redundant paths to server bays In a dual pass-thru module configuration, redundant Ethernet signals from each server blade are routed through the enclosure backplane to separate pass-thru modules within the enclosure. This configuration provides redundant paths to each server bay. Redundant Ethernet signals from each blade server are routed through the enclosure backplane to separate pass-thru modules within the enclosure. However, port to server mapping varies based on the type of server blade installed. XModem The pass-thru module supports XModem for transferring files during firmware upgrade using the serial management port. XModem sends blocks of data and includes an error-detection system called a checksum. When the data is received, the error detection system ensures that the entire message reached its destination. If not, the receiving computer sends a request for data retransmission. Introduction 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

Introduction 6
Port mapping
For detailed port mapping information, see the
HP BladeSystem Enclosure Quick Setup Guide
or the
HP
BladeSystem Enclosure Setup and Installation Guide
on the HP website
(
).
Dual pass-thru modules
In a dual pass-thru module configuration, two pass-thru modules in the HP BladeSystem c7000 Enclosure
provide redundant paths to the network ports on the server blades.
Redundant paths to server bays
In a dual pass-thru module configuration, redundant Ethernet signals from each server blade are routed
through the enclosure backplane to separate pass-thru modules within the enclosure. This configuration
provides redundant paths to each server bay.
Redundant Ethernet signals from each blade server are routed through the enclosure backplane to
separate pass-thru modules within the enclosure. However, port to server mapping varies based on the
type of server blade installed.
XModem
The pass-thru module supports XModem for transferring files during firmware upgrade using the serial
management port. XModem sends blocks of data and includes an error-detection system called a
checksum. When the data is received, the error detection system ensures that the entire message reached
its destination. If not, the receiving computer sends a request for data retransmission.