Chapter 3 Rear of HP NetServer Left Rear Rack Column Rack-Mounting the HP NetServer Cable Management Arm Figure 3-16. Attaching the Cable Management Arm 5. Attach the other flange of the cable arm to the rear column of the rack with the two M6 screws, included with the non-HP rack kit. 6. Attach the flange to the NetServer with the two 2-32 pan head Torx T-20 screws, included with the Arm. See Figure 3-16. 7. Extend the NetServer out of the rack to ensure the Cable Management Arm moves along with the chassis without binding. NOTE Refer to the HP NetServer LC 2000r Rack Cabling Reference Guide, for information about cable dressing and routing. 8. If the Cable Management Arm moves with the chassis and the rack installation appears to be successful, slide the NetServer into the rack. The NetServer should click into the latches on the two column adapters. 9. If the NetServer is not in a restricted-access area, tighten both slide securing screws on the bezel latching mechanisms. See Figure 3-16. 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

Chapter 3
Rack-Mounting the HP NetServer
27
Rear of HP NetServer
Left Rear
Rack Column
Cable Management Arm
Figure 3-16. Attaching the Cable Management Arm
5.
Attach the other flange of the cable arm to the rear column of the rack
with the two M6 screws, included with the non-HP rack kit.
6.
Attach the flange to the NetServer with the two 2-32 pan head Torx T-20
screws, included with the Arm. See Figure 3-16.
7.
Extend the NetServer out of the rack to ensure the Cable Management
Arm moves along with the chassis without binding.
NOTE
Refer to the
HP NetServer LC 2000r Rack Cabling Reference
Guide
, for information about cable dressing and routing.
8.
If the Cable Management Arm moves with the chassis and the rack
installation appears to be successful, slide the NetServer into the rack.
The NetServer should click into the latches on the two column adapters.
9.
If the NetServer is not in a restricted-access area, tighten both slide
securing screws on the bezel latching mechanisms.
See Figure 3-16.