HP LH4r HP Netserver LC 3 NetRAID-3Si Installation Guide - Page 6

Local Storage, Shared Storage

Page 6 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots: Local Storage Physical drive location Disk drives Controller SCSI bus Shared Storage Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SPU I/O slot SCSI ID Channels RAID level Logical disks Configuration options: HP NetServer LC3 400, 450, 500, 550 MHz. 1 - 2, but must be the same number of CPUs in each server 4.06.23 PQ Any size 64 MB minimum. Must be HP. Internal or external, using any controller. Must use HP disks. See Local Storage below. P5 - Shared storage controller P4 - Intra-cluster (Heartbeat) LAN P1 - Client LAN All others - Any other plug-in cards. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP May use SPU embedded controller, NetRAID-3Si, or any controller (any number, manufacturer or driver) in any available I/O slot. May not use NetRAID-1 or NetRAID-3. Any HP cables that meet SCSI specifications and any SCSI bus speed HP NetRAID 3Si Adapter D5955A 1 W.01.20 or later B.01.10 or later 2.22 or later A.01.15 or later P6 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array Cluster mode on Cache write-policy to write-thru Set any other options as you prefer 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

2
SPU
Model
HP NetServer LC3
Clock speed
400, 450, 500, 550 MHz.
No. of CPUs
1 – 2, but must be the same number of CPUs in each server
BIOS version
4.06.23 PQ
CPU cache
Any size
RAM
64 MB minimum.
Must be HP.
Local storage
Internal or external, using any controller. Must use HP disks.
See
Local
Storage
below.
I/O slots:
P5 - Shared storage controller
P4 – Intra-cluster (Heartbeat) LAN
P1 – Client LAN
All others - Any other plug-in cards.
Local Storage
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12)
Disk drives
Must be HP
Controller
May use
SPU embedded controller, NetRAID-3Si, or any controller (any
number, manufacturer or driver) in any available I/O slot.
May not use
NetRAID-1 or NetRAID-3.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared Storage
Controller
Model
HP NetRAID 3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.20 or later
BIOS
B.01.10 or later
Driver
2.22 or later
NetRAID Assistant
A.01.15 or later
SPU I/O slot
P6
SCSI ID
6, 7
Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array
Configuration
options:
Cluster mode on
Cache write-policy to write-thru