HP ProLiant BL420c HP ProLiant BL420c Gen8 Server Blade Maintenance and Servic - Page 39
NAND flash module for the Smart Array P220i Controller
View all HP ProLiant BL420c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
To replace the component: 1. Install the drive backplane on the front panel/drive cage assembly. 2. Install the front panel/drive cage assembly ("Front panel/drive cage assembly" on page 43). 3. Install the hard drives ("Drive" on page 26). 4. Install the hard drive blanks ("Drive blank" on page 26). 5. Install the access panel ("Access panel" on page 25). NAND flash module for the Smart Array P220i Controller The Smart Array P220i Controller is an option for this server blade and ships standard with a capacitor pack and a NAND flash module. To remove the component: 1. Power down the server blade (on page 23). 2. Remove the server blade (on page 24). 3. Remove the access panel ("Access panel" on page 25). 4. Disconnect the capacitor pack cabling, if connected ("FBWC capacitor pack cabling" on page 67). 5. Remove the SAS controller ("SAS controller" on page 28). 6. Lift the handle on the SAS controller, and then remove the T-15 screw from the NAND flash module bracket. Removal and replacement procedures 39