HP ProLiant CL380 Compaq ProLiant CL380 User Guide - Page 60

Temperature Requirements

Page 60 highlights

Installing the ProLiant CL380 Rack Model 3-7 Temperature Requirements To ensure continued safe and reliable operation of the equipment, place the system in a well-ventilated, climate-controlled environment. The Compaq Maximum Recommended Ambient Operating Temperature (TMRA) for most server products is 35°C (95°F). Therefore, do not allow the temperature in the room where the rack is located to exceed 35°C (95°F). The operating temperature inside the system will always be higher than the room temperature and will depend on the configuration of equipment in your system. The maximum internal system temperature for your configuration should not exceed the values in the following table. Table 3-1 Rack Model ProLiant 380 Internal Temperature Maximums Equipment Included Rack Model ProLiant CL380 Compaq server options Other manufacturers' options Maximum Internal System Temperature 50°C/122°F 40°C/104°F See other manufacturers' specifications CAUTION: To reduce the risk of damage to the equipment when installing third-party options: Ensure that the option equipment does not impede airflow to the rack-mountable system or increase the internal rack temperature beyond the Compaq specified maximum rating. Ensure that the Manufacturer's Maximum Recommended Ambient Operating Temperature of the option equipment is not exceeded when installed in the rack.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253

Installing the ProLiant CL380 Rack Model
3-7
Temperature Requirements
To ensure continued safe and reliable operation of the equipment, place the
system in a well-ventilated, climate-controlled environment.
The Compaq Maximum Recommended Ambient Operating Temperature
(TMRA) for most server products is 35°C (95°F). Therefore, do not allow the
temperature in the room where the rack is located to exceed 35°C (95°F).
The operating temperature inside the system will always be higher than the
room temperature and will depend on the configuration of equipment in
your system.
The maximum internal system temperature for your configuration should not
exceed the values in the following table.
Table 3-1
Rack Model ProLiant 380 Internal Temperature Maximums
Equipment Included
Maximum Internal System Temperature
Rack Model ProLiant CL380
50°C/122°F
Compaq server options
40°C/104°F
Other manufacturers’ options
See other manufacturers’ specifications
CAUTION:
To reduce the risk of damage to the equipment when installing
third-party options:
Ensure that the option equipment does not impede airflow to the
rack-mountable system or increase the internal rack temperature beyond
the Compaq specified maximum rating.
Ensure that the Manufacturer’s Maximum Recommended Ambient
Operating Temperature of the option equipment is not exceeded when
installed in the rack.