The E_D_TOV must be, The E_D_TOV is entered
![]() |
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 112 highlights
Error Messages Message Error 17: Invalid E_D_TOV Error 18: Invalid TOV Error 20: Invalid Preferred Domain ID Error 21: Invalid Switch Priority Error 29: Invalid Gateway Address Description The value entered for the error detection time-out value is invalid. The E_D_TOV and R_A_TOV values are not compatible. The value entered for the preferred domain ID for the Director or Switch is invalid. The value entered for the switch priority is invalid. The value entered for the gateway address is invalid. Action The E_D_TOV is entered in tenths of a second and must be entered as an integer in the range 2-600 (0.2 second to 60 seconds). The E_D_TOV must be smaller than the R_A_TOV. Check to be sure that all conditions are met and re-submit. Enter a valid E_D_TOV / R_A_TOV combination. The E_D_TOV must be smaller than the R_A_TOV. The preferred domain ID must be an integer in the range 1-31. Enter an appropriate value and re-submit. The switch priority entered for the Director or Switch must be one of the following: principal, never principal, or default. Enter an appropriate value and re-submit. The new gateway address for the Ethernet interface must be entered in dotted decimal format (for example, 0.0.0.0). Enter an appropriate gateway address and re-submit. A-4 embedded web server user guide