Error 236: Ambiguous, Feature Key
View all HP StorageWorks 2/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Error Messages Message Error 235: Unrecognized Command Error 236: Ambiguous Command Error 237: Invalid Zoning Database Error 238: Invalid Feature Key Error 239: Fabric binding entry not found Description Cannot recognize the command and cannot perform the help '?' command as requested. Cannot recognize the command issued. There was an unidentifiable problem in the local zone set work area. The feature key entered is invalid. The user requested to remove a fabric binding entry that is not in the pending fabric membership list. Action The entered command is misspelled or the prompt is not positioned at the right place. For the appropriate syntax, see the section of the manual that corresponds to the attempted command. The command cannot be interpreted because a unique match cannot be identified. For the appropriate syntax, see the section of the manual that corresponds to the attempted command. Enter the complete command and re-submit. Verify all parameters are entered correctly and re-submit. Otherwise, the pending zone set should be cleared and reconstructed. Verify that the feature key was entered correctly and re-submit. Contact your service representative with further difficulties. Verify that the correct entry (both WWN and Domain ID) is being requested for removal from the list and re-submit the request. embedded web server user guide A-21