HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.x Fabric Watch Administrator - Page 39

value of 80 is the new trigger point. This example shows how to apply the custom value; unless

Page 39 highlights

Fabric Watch displays the units of measurement (Unit), time base (Time base), low threshold (Low), high threshold (High) and buffer size (BufSize) for each column. See the following screen. In this example, a value of 80% is chosen as the custom high value for RXPerformance. The default value is 10. 1 : change behavior type 11 : change threshold alarm level 2 : change behavior interval 12 : change changed alarm 3 : change threshold boundary level 13 : change below alarm 4 : change custom unit 14 : change above alarm 5 : change custom time base 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18] 7 Enter high threshold => : (0..100) [0] 80 Index ThresholdName 8 eportRXPerf008 17 eportRXPerf017 26 eportRXPerf026 27 eportRXPerf027 28 eportRXPerf028 29 eportRXPerf029 BehaviorType Triggered Triggered Triggered Triggered Triggered Triggered BehaviorInt 1 1 1 1 1 1 Threshold boundary level is set at : Default Unit Time base Low High BufSize Default Percentage(%) minute 0 100 0 Custom Percentage(%) minute 0 80 0 . . . The next two screens show how to change the threshold boundary level to custom so that the new custom value of 80 is the new trigger point. This example shows how to apply the custom value; unless you apply Fabric OS 5.x Fabric Watch administrator guide 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Fabric OS 5.x Fabric Watch administrator guide
39
Fabric Watch displays the units of measurement (Unit), time base (Time base), low threshold (Low), high
threshold (High) and buffer size (BufSize) for each column. See the following screen.
In this example, a value of 80% is chosen as the custom high value for RXPerformance. The default value is
10.
The next two screens show how to change the threshold boundary level to custom so that the new custom
value of 80 is the new trigger point. This example shows how to apply the custom value; unless you apply
1
: change behavior type
11 : change threshold alarm level
2
: change behavior interval
12 : change changed alarm
3
: change threshold boundary level
13 : change below alarm
4
: change custom unit
14 : change above alarm
5
: change custom time base
15 : change inBetween alarm
6
: change custom low
16 : apply threshold alarm changes
7
: change custom high
17 : cancel threshold alarm changes
8
: change custom buffer
18 : return to previous page
9
: apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 7
Enter high threshold => : (0..100) [0] 80
Index ThresholdName
BehaviorType
BehaviorInt
8 eportRXPerf008
Triggered
1
17 eportRXPerf017
Triggered
1
26 eportRXPerf026
Triggered
1
27 eportRXPerf027
Triggered
1
28 eportRXPerf028
Triggered
1
29 eportRXPerf029
Triggered
1
Threshold boundary level is set at : Default
Default
Custom
Unit
Percentage(%)
Percentage(%)
Time base
minute
minute
Low
0
0
High
100
80
BufSize
0
0
.
.
.