Table 22 Port Class threshold defaults (continued) Area Description Default threshold settings Primitive Sequence Protocol Error Receive Performance State Changes Transmit Performance Monitors the number of primitive sequence errors Unit: error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Monitors receive rate, by percentage Unit: percentage Time Base: minute Low: 0 High: 100 Buffer: 0 Monitors state changes Unit: error(s) Time Base: minute Low:0 High: 5 Buffer: 0 Monitors transmission rate, by percentage Unit: percentage Time Base: minute Low: 0 High: 100 Buffer: 0 Default alarm settings Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Threshold state Informative Informative Out_of_range In_range Informative Informative Informative Informative Informative Informative Out_of_range In_range Informative Informative Informative Informative Table 23 provides default settings for areas in the E-Port class. Table 23 E-Port class threshold defaults Area Invalid CRC Count Invalid Transmission Word Link Failure Count Loss of Signal Count Description Default threshold settings Monitors the number of CRC errors Unit: error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Monitors the number of invalid words transmitted Unit: error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Monitors the number of link failures Unit: error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Monitors the number of signal loss errors Unit: error(s) Time Base: minute Low: 0 High: 5 Buffer: 0 Default alarm settings Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Threshold state Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Informative Informative Out_of_range In_range Fabric OS 5.x Fabric Watch administrator guide 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Fabric OS 5.x Fabric Watch administrator guide
63
Table 23
provides default settings for areas in the E-Port class.
Primitive
Sequence
Protocol Error
Monitors the
number of
primitive
sequence errors
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive
Performance
Monitors receive
rate, by
percentage
Unit: percentage
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
State Changes
Monitors state
changes
Unit: error(s)
Time Base: minute
Low:0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit
Performance
Monitors
transmission
rate, by
percentage
Unit: percentage
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Table 23
E-Port class threshold defaults
Area
Description
Default threshold
settings
Default alarm
settings
Threshold
state
Invalid CRC
Count
Monitors the
number of CRC
errors
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid
Transmission
Word
Monitors the
number of invalid
words transmitted
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure
Count
Monitors the
number of link
failures
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of Signal
Count
Monitors the
number of signal
loss errors
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Table 22
Port Class threshold defaults (continued)
Area
Description
Default threshold
settings
Default alarm
settings
Threshold
state